Installing the MPU
4.1
Face the front panel of the device. Remove the filler panel from the target slot.
1.
This example uses slot 0 on the device.
Place the MPU horizontally on a workbench with the PCB facing up. Pull outward the ejector
2.
levers on the MPU.
Gently push the MPU into the slot along the guide rails.
3.
Push the ejector levers inward until the MPU is in close contact with the backplane.
4.
Use a Phillips screwdriver to tighten the captive screws on the MPU.
5.
Figure 2 Installing the MPU
Removing the MPU
4.2
Use a Phillips screwdriver to loosen the captive screws on the MPU until all pressure is
1.
released.
Simultaneously pull the ejector levers at both sides of the MPU outward to separate the MPU
2.
from the backplane, and pull the MPU slowly out of the chassis along the guide rails.
Place the MPU on an anti-static workbench with the PCB facing up, or put it in an anti-static
3.
bag.
If you are not to install a new MPU, install a filler panel in the slot to prevent dust and ensure
4.
good ventilation in the device.
5 Software upgrade
For information about upgrading the MPU, see the release notes.
6 Obtaining documentation
To access the most up-to-date H3C product documentation on the H3C website at www.h3c.com.hk:
Go to http://www.h3c.com.hk/Technical_Documents.