Electrical connection

Danger of injury! All electrical work
should be undertaken by a suitably
qualified and competent person in strict
accordance with current national and
local safety and building code
regulations. Installation, repairs and
other work by unqualified persons
could be dangerous. Miele cannot be
held liable for unauthorised work.
Ensure power is not supplied to the
appliance until after installation or repair
work has been carried out. The
appliance is supplied with a mains
connection cable for connection to AC
50 Hz, 230 V.
The fuse rating must be at least 10 A.
Connection should be made via a fused
connection unit or suitable isolator
which complies with national and local
safety regulations. For extra safety, it is
advisable to protect the appliance with
a suitable residual current device (RCD)
with a trip current of 30 mA.
Connection to a switched socket is
recommended as this provides easier
access in the case of a service call.
If the switch is not accessible after
installation, an additional means of
disconnection must be provided for all
poles.
When switched off there must be an all-
pole contact gap of 3 mm in the isolator
switch (including switch, fuses and
relays according to EN 60335).
The voltage, rated load and fuse rating
are given on the data plate situated at
the front of the oven interior. Please
ensure that these match the household
mains supply.
108
If the connection cable is damaged, it
must be replaced by a Miele approved
service technician in order to avoid a
hazard.