Electrical Connection - Miele DGC7840 Operating And Installation Instructions

Steam combination oven
Table of Contents

Advertisement

Electrical connection

We recommend that you connect the
steam oven to the electricity supply
using a suitable switched electrical
socket. This simplifies servicing. The
socket must be easily accessible after
the steam oven has been installed.
Risk of damage from incorrect
connection.
Danger of injury! Miele cannot be
held liable for unauthorised
installation, maintenance and repair
work as this can be dangerous to
users.
Miele cannot be held liable for
damage or injury (e.g. electric shock)
caused by the lack of or inadequacy
of an on-site earthing system.
If the plug is removed from the
connection cable or if the cable is
supplied without a plug, the steam
oven must be connected to the
electrical supply by a suitably
qualified and competent electrician.
If the socket is no longer accessible,
or if a hard-wired connection is
planned, an additional means of
disconnection must be provided for
all poles. Suitable means of
disconnection include switches with
an all-pole contact gap of at least
3 mm. These include miniature circuit
breakers, fuses and relays. The
connection data is given on the data
plate. Please ensure this information
matches the household mains
electricity supply.
After installation, ensure that all
electrical components are shielded
and cannot be accessed by users.
Total power output
See data plate.
Connection data
The connection data is given on the
data plate. Please ensure this
information matches the household
mains supply.
Residual current device
For extra safety, it is advisable to
protect the steam oven with a suitable
residual current device (RCD) with a trip
range of 30 mA.
Replacing the mains connection
cable
If replacing the mains connection cable,
it must be replaced with a cable type
H 05 VV-F, available from Miele.
Disconnecting from the mains
Risk of electric shock!
There is a risk of electric shock if the
appliance is connected to the mains
electricity supply during repair or
service work.
After disconnection, ensure the
appliance cannot be switched back
on by mistake.
Installation
183

Advertisement

Table of Contents
loading

Table of Contents