Corriente Máxima
Modelo del Convertidor
de Frenado (I
CFW11 0006 B 2
CFW11 0006 S 2 O FA
CFW11 0007 B 2
CFW11 0007 S 2 O FA
CFW11 0007 T 2
CFW11 0010 S 2
CFW11 0010 T 2
CFW11 0013 T 2
CFW11 0016 T 2
CFW11 0024 T 2
CFW11 0028 T 2
CFW11 0033 T 2
CFW11 0045 T 2
CFW11 0054 T 2
CFW11 0070 T 2
CFW11 0086 T 2
CFW11 0105 T 2
CFW11 0003 T 4
CFW11 0005 T 4
CFW11 0007 T 4
CFW11 0010 T 4
CFW11 0013 T 4
CFW11 0017 T 4
CFW11 0024 T 4
CFW11 0031 T 4
CFW11 0038 T 4
CFW11 0045 T 4
CFW11 0058 T 4
CFW11 0070 T 4
CFW11 0088 T 4
CFW11 0142 T 2 O DB
CFW11 0180 T 2 O DB
CFW11 0211 T 2 O DB
CFW11 0105 T 4 O DB
CFW11 0142 T 4 O DB
CFW11 0180 T 4 O DB
CFW11 0211 T 4 O DB
Notas:
(1) La corriente eficaz de frenado presentada es apenas un valor ilustrativo, ya que depende de la razón cíclica del frenado en la aplicación. Para obtener la corriente eficaz de frenado utilice la ecuación
de abajo, donde t
es dado en minutos y corresponde a la suma de los tiempos de actuación del frenado durante el más severo ciclo de 5 minutos.
br
t
I
= I
·
br
eficaz
máx
5
(2) Los valores de P
y P
(potencia máxima y media del resistor de frenado respectivamente) presentados son válidos para los resistores recomendados y para las corrientes eficaces de frenado
máx
R
presentados en la tabla de arriba. La potencia del resistor debe ser modificada de acuerdo con la razón cíclica del frenado.
Tabla A.3: Especificaciones del frenado reostático para mecánicas A a E
Potencia Máxima
Corriente Eficaz de
(de pico) de
)
Frenado
max
[A]
(P
)
(2)
max
[kW]
5.3
2.1
5.3
2.1
7.1
2.9
7.1
2.9
5.3
2.1
11.1
4.4
7.1
2.9
11.1
4.4
14.8
5.9
26.7
10.7
26.7
10.7
26.7
10.7
44
17.6
48.8
19.5
48.8
19.5
93
37.2
111.1
44.4
3.6
2.9
5.3
4.3
5.3
4.3
8.8
7
10.7
8.5
12.9
10.3
17
13.6
26.7
21.3
36.4
29.1
47.1
37.6
53.3
42.7
66.7
53.3
87.9
70.3
266.7
106.7
266.7
106.7
333.3
133.3
186
148.8
266.7
213.3
266.7
213.3
363.6
290.9
Potencia (media)
Disipada en
Frenado
el Resistor de
Recomendado
(I
)
eficaz
Frenado (P
)
(2)
[A]
R
[kW]
5.2
2.03
5.2
2.03
6.96
2.71
6.96
2.71
5.2
2.03
10.83
4.22
6.96
2.71
8.54
2.62
14.44
5.63
19.15
5.5
18.21
4.97
16.71
4.19
33.29
10.1
32.17
8.49
26.13
5.6
90.67
35.3
90.87
29.7
3.54
2.76
5.2
4.05
5.2
4.05
8.57
6.68
10.4
8.11
12.58
9.81
16.59
12.9
20.49
12.6
26.06
14.9
40
27.2
31.71
15.1
42.87
22.1
63.08
36.2
142
30.2
180
48.6
211
53.4
105
47.4
142
60.5
180
97.2
191.7
80.8
Guía de Instalación
Resistor
Cableado de Potencia
(bornes DC+ y BR)
[Ω]
[mm
(AWG)]
2
75
1.5 (16)
75
1.5 (16)
56
1.5 (16)
56
1.5 (16)
75
1.5 (16)
36
2.5 (14)
56
1.5 (16)
36
2.5 (14)
27
4 (12)
15
6 (10)
15
6 (10)
15
6 (10)
9.1
10 (8)
8.2
10 (8)
8.2
6 (8)
4.3
35 (2)
3.6
35 (2)
220
1.5 (16)
150
1.5 (16)
150
1.5 (16)
91
2.5 (14)
75
2.5 (14)
62
2.5 (12)
47
4 (10)
30
6 (10)
22
6 (8)
17
10 (8)
15
10 (8)
12
10 (6)
9.1
25 (4)
1.5
70 (2/0) o 2x 25 (2x 4)
1.5
120 (4/0) o 2x 35 (2x 2)
1.2
150 (300) o 2x 50 (2x 1)
4.3
50 (1)
3
70 (2/0) o 2x 25 (2x 4)
3
120 (4/0) o 2x 35 (2x 2)
2.2
120 (250) o 2x 50 (2x 1)