Troubleshooting - EIP CD30 Owner's Manual

Hide thumbs Also See for CD30:
Table of Contents

Advertisement

S
YMPTOM
Little or no airflow
Little or no water
extraction
Little or no defrost
when required

TROUBLESHOOTING

C
AUSE
1. Loose fan on shaft
2. Fan motor burnt out
3. Dirty refrigeration coils
4. Loose electrical wiring
5. Control humidistat either
set too high or
malfunctioning
1. Insufficient air flow
2. Compressor fault
3. Loss of refrigerant gas
1. Faulty Timer
2. Faulty bypass timer
Page 10 of 16
Drawing : - TPC137
Issue
: - 7
Date
: - 23/11/16
R
EMEDY
1. Tighten fan
2. Replace the fan motor
3. See Routine Maintenance
Section
4. Check the wiring diagram
to find fault and repair
5. Adjust humidistat as
required or replace
1. Check all of the above
2. Contact the Factory
Service Center
3. Contact the Factory
Service Center
1. Contact the Factory
Service Center
2. Contact the Factory
Service Center