6-22 UK/Plessey
Read:
Format
Data digits (variable)
Check digit verification: The UK/Plessey has two optional check digits.
Check digit transmission: By setting Enable, check digit will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of Code 39.
Code ID setting: Refer to Code ID setting of UPC-A.
Insertion group selection: Refer to Insertion group selection of UPC-A.
Parameter name
Read
Check digit verification
Check digit transmission
Max. code length
Min. code length
Code ID setting
Insert group selection
Reserved
2 check digits (optional)
FS01 & MS3391-L
Para. code
Para. option
Disable
0x09 0x61
Enable
Disable
0x09 0x62
Enable
Disable
0x09 0x63
Enable
00-99
0x09 0x64
00-99
0x09 0x65
00-FF
0x09 0x66
(ASCII)
00-44
0x09 0x67
0x09 0x68
Para. value
00
01*
00
01*
00*
01
00-99
99*
00-99
01*
00-FF
16
16
<U>*
00-44
00*
50
Reserved
Parameter (Para. No.)
UK_Plessey
(0xF2 0x90)
UK_PlesseyCheckDigitVerification
(0xF2 0x91)
UK_PlesseyTransmitCheckDigit
(0xF2 0x92)
Set Lengths for UK_Plessey
L1: (0xF2 0x93)
L2: (0xF2 0x94)
Note1
UK_Plessey_CodeIDSetting
(0xF2 0x95)
UK_Plessey_InsertGroupSelection
(0xF2 0x96)
-
Para.
value
00
01*
00
01*
00*
01
00*
00*
<U>*
00-44
00*
-

Advertisement