6-13 Industrial 2 of 5

Read:
Format
Max./Min. code length: Refer to Max./Min. code length of Code 39.
Code ID setting: Refer to Code ID setting of UPC-A.
Insertion group selection: Refer to Insertion group selection of UPC-A.
Parameter name
Read
Max. code length
Min. code length
Code ID setting
Insert group selection
Reserved
Data digits (variable)
FS01 & MS3391-L
Para. code
Para. option
Disable
0x06 0xA5
Enable
00-99
0x06 0xA6
00-99
0x06 0xA7
00-FF
0x06 0xA8
(ASCII)
00-44
0x06 0xA9
0x06 0xAA
Para. value
00*
01
00-99
99*
00-99
04*
00-FF
16
16
<H>*
00-44
00*
39
Reserved
Parameter (Para. No.)
Industrial2of5
(0x05)
Set Length(s) for Industrial2 of 5
L1:(0x14)
L2:(0x15)
Note 1
Industrial2of5_CodeIDSetting
(0xF2 0x5B)
InsertGroupSelection
(0xF2 0x5C)
-
Para.
value
00*
01
12*
12*
<G>*
00-44
00*
-