Gs1 Databar Limited - Generalscan FS01&MS3391-L Configration User Manual

Laser barcode scanner
Table of Contents

Advertisement

6-25 GS1 DataBar Limited

Read:
Format
Code ID setting: Refer to Code ID setting of UPC-A.
Insertion group selection: Refer to Insertion group selection of UPC-A.
Conversion: Refer to Conversion of GS1 DataBar (GS1 DataBar Truncated).
Parameter name
Read
Code ID setting
Insert group selection
Conversion
Reserved
FS01 & MS3391-L
Para. code
Para. option
Disable
0x0A 0xF1
Enable
00-FF
16
0x0A 0xF2
(ASCII)
00-44
0x0A 0xF3
None
0x0A 0xF4
UCC/EAN 128
UPC-A or EAN-13
0x0A 0xF5
16 Data digits
Para. value
00
01*
00-FF
16
<R >*
00-44
00*
00*
01
02
53
Reserved
Parameter (Para. No.)
RSS-Limited (0xF0 0x53)
RSS-Limited_CodeIDSetting
(0xF2 0xAB)
RSS-Limited_InsertGroupSelection
(0xF2 0xAC)
Convert RSS to UPC/EAN
(0xF0 0X8D)
Note1
-
Para.
value
00*
01
<R >*
00
00*
FF
16
01
-

Advertisement

Table of Contents
loading