6-19 Code 93
Read:
Format
Check digit verification: The check digit verification is optional.
Check digit transmission: By setting Enable, check digit will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of Code 39.
Code ID setting: Refer to Code ID setting of UPC-A.
Insertion group selection: Refer to Insertion group selection of UPC-A.
Parameter name
Read
Check digit verification
Check digit transmission
Max. code length
Min. code length
Code ID setting
Insert group selection
Reserved
Data digits (variable)
FS01 & MS3391-L
Para. code
Para. option
Disable
0x08 0x35
Enable
Disable
0x08 0x36
Enable
Disable
0x08 0x37
Enable
00-99
0x08 0x38
00-99
0x08 0x39
00-FF
0x08 0x3A
(ASCII)
00-44
0x08 0x3B
0x08 0x3C
2 check digits (optional)
Para. value
00
01*
00
01*
00*
01
00-99
99*
00-99
01*
00-FF
16
16
<L>*
00-44
00*
46
Reserved
Parameter (Para. No.)
Code 93 (0x09)
Code93_CheckDigitVerification
(0xF2 0x79)
Code93_TransmitCheckDigit
(0xF2 0x7A)
Set Length(s) for Code 93
L1:(0x1A)
L2:(0X1B)
Note1
Code93_CodeIDSetting
(0xF2 0x7B)
Code93_InsertGroupSelection
(0xF2 0x7C)
-
Para.
value
00*
01
00
01*
00*
01
04*
55*
<E>*
00-44
00*
-