Error Log Functions
Error
code
(Hex)
0101
Transmission failed because the local node is
not participating in the network.
0105
Transmission failed because of a node address
setting error.
0106
Transmission failed because of a node address
duplication error.
0107
Transmission failed because the other node is
not participating in the network.
0108
Transmission failed because there is no Unit
with the specified unit number.
0109
Transmission failed because the other node is
busy.
010B
Transmission failed because of a CPU Unit
error. Frame discarded due to one of the follow-
ing:
• A cyclic service monitoring timeout occurred.
• A CPU Unit watchdog timer error occurred.
• Another CPU Unit error occurred.
010D
Transmission failed because the destination
address is not registered in the routing table.
010E
Transmission failed because the routing table
has not been registered.
010F
Transmission failed because of a routing table
error.
0110
Transmission failed because of too many repeti-
tions.
0111
Transmission failed because the command
exceeded the max. command length.
0112
Transmission failed because of a header error.
0117
Packet discarded because the internal recep-
tion buffer is full.
0118
Illegal packet discarded.
0120
Unexpected routing error
0123
Packet discarded because the internal trans-
mission buffer is full.
0124
Routing failed because maximum frame length
was exceeded.
0125
Packet discarded because of response timeout.
021A
Setting table logic error
0211
Node address duplication (cause)
0300
Packet discarded because of parameter error.
0340
Bus Off detected
0341
Network power supply error
0342
Transmission timeout
226
Error
Detail code
First byte
FINS message communications command:
Bit 15: OFF
Bits 14 to 8: SNA
Bits 7 to 0: SA1
FINS message communications response:
Bit 15: ON
Bits 14 to 8: DNA
Bits 7 to 0: DA1
Explicit message communications command:
Bit 15: OFF
Bits 14 to 8: 0
Bit 7: ON
Bits 6 to 0: Node address of command source
Explicit message communications response:
Bit 15: ON
Bits 14 to 8: 0
Bit 7: ON
Bits 6 to 0: Node address of command source
00 Hex
03 Hex: Routing table
0A Hex: Master scan list
0B Hex: Slave scan list
0C Hex: Message moni-
toring timer list
0D Hex: Scan time
00 Hex
Local node address
Same as the code (such as 0101 Hex) in the dis-
carded FINS/explicit message packet.
00 Hex
00 Hex
00 Hex
00 Hex
00 Hex
00 Hex
Section 9-2
Record
stored in
Second byte
EEPROM
No
Yes
No
No
No
No
No

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cj1w-drm21Cs1w-drm21-v1

Table of Contents