Fujitsu primequest 2400E2 Design Manual page 94

2000 series
Table of Contents

Advertisement

3.3.4 HDD Configuration (2/5)
Notes (2/2)
When internal HDDs are used, the hardware RAID controller may fail to fully detect failures on a hard disk,
and a system slowdown may occur.
[Additional Notes]
If intermittent media errors occur on a HDD, a slowdown may occur on rare occasions.
This problem may occur for example due to many scratches in a wide area on the HDD. The RAID
controller tries to replace the media error area and salvage data using RAID parity. Therefore, if
intermittent media errors occur over a long time, the salvage processing takes a longer time and the
conventional media access processing is delayed.
If there are restrictions in operation, the following options are recommended.
- Use ETERNUS.
- Replace the HDD with a SAS-SSD.
When using an internal SSD for a PCI slot, note the following points.
- The SSD cannot be used as a boot drive.
- When a failed SSD is replaced, the integrity of the data in the drive cannot be guaranteed. Reliability
design including recovery from a regular backup and software RAID configuration is required to prepare
for possible risks.
When using an internal HDD in an SB, note the following points.
When the HDD is used as a boot drive or a data disk and the Reserved SB function is used, the HDD
cannot be started or operated.
PRIMEQUEST 2000 Series Design Guide