3.2.2 Functions That are Used for Partition Configuration - Reserved SB (2/6)
Wait Time for Reserved SB Switching
From 0 to 99 minutes can be set for the shutdown wait time when a Reserved SB
that is used in another partition is switched by using the MMB Web-UI (the
default setting is 10 minutes).
If the partition cannot be shut down after a specified time has passed, the
Reserved SB is forced to be activated.
Saving the Partition Configuration Information
Before Reserved SB switching is performed, the partition configuration
information for the entire cabinet is automatically saved to the MMB.
The latest partition configuration information overwrites the existing
information right before a Reserved SB replaces the failed SB (before the system
reboots).
The saved information can be viewed from the MMB Web-UI.
Memory Scale-up Board
Memory Scale-up Boards cannot be used as the source or the target of Reserved
SB switching.
PRIMEQUEST 2000 Series Design Guide
68