Mounting only for instruments with detachable calculators!

11 Mounting with Wall support

When the calculator is detached from the fl ow sensor it
must be mounted on the wall using the mounting support.
The display must remain accessible and able to be read out
without auxiliary tools.
The wall mounting kit included in delivery for F90M AMS
separable version:
2 screws
2 dowels
1 double-sided sticker pad
1 wall mounting support
A. Mounting with a sticker pad
Press the locking positions on the side of the adapter lightly with
one hand while pulling up the calculator housing with the other
hand.
Latch the wall mounting support onto instrument. Remove the
protective foil from the sticker pad and press the pad fi rmly onto
the wall support.
Remove the second protective foil from the sticker pad and press
the instrument with the wall mounting suport fi rmly in place on the
wall.
Elster Messtechnik GmbH, Otto-Hahn-Straße 25, 68623 Lampertheim
Tel: +49 (0) 6206 933 0, Fax: +49 (0) 6206 933 100, www.elstermesstechnik.com
Artikel-Nr. 0080100072 - 2010-08-23 (F90MAMS_M_09.03e / 08.10)
Important:
B. Mounting with dowels
Press the locking positions on the side of the adapter lightly with
one hand while pulling up the calculator housing with the other
hand.
Drill holes for the dowels (Ø 6 mm, depth 40 mm). Take into
account the maximum length of the connecting cable (300 mm)
between the fl ow sensor and the heat meter.
Screw on the wall mounting support.
Attach the instrument to the mounting support.
C. Removing the heat meter from the mounting suppor
Pull the instrument upwards and away from the wall.
Subject to technical change!
Return shipment of the lithium batteries must be carried out
appropriately.