If the same point as in the start-up block is specified in the succeeding block, an alarm will result
if the successive two blocks after that do not have dimension words, X and Z.
Faulty program example 1:
N1
G01
X50
Z100 F0.2
N2
G42
N3
X50
Z100
N4
X60
Z80
N5
X100
Z50
Since sequence N3 designates a point identical to the one designated in the start-up sequence
N2, an alarm occurs.
Faulty program example 2:
N1
G01
X50
Z100 F0.2
N2
G42
N3
N4
N5
X50
Z100
N6
X60
Z80
Since sequences N3 and N4, the successive two sequences after the start-up of the tool nose
radius compensation mode, do not contain X and Z axis movement commands, an alarm
occurs.