SECTION 11 PROGRAMMING FOR SIMULTANEOUS 4-AXIS CUTS (2S Model)
The blocks dominated by the respective G codes, G13 and G14, are continuous as a program.
That is, N0101 directly follows N0049 and N0151 follows N0099. Therefore, when the S, T, and
M commands in these blocks are the same as designated in N0001 and N0051, respectively,
they can be omitted.
Blocks containing S and M commands (M41 through M44, M00, M01, M03, M04 and M05) for
turrets A and B, or a G96 code, must also contain P commands assigned the same number (up
to four digits) to synchronize the execution of the commands in those blocks at turrets A and B.
When synchronization of command execution at the two turrets is required, use the P
command.
Program example:
%
O0100
N0000
G13
N0001
G00
X800
Z800
N0002
X1
Z1
N0050
G01
X
Z2
N0098
G00
X80.0
Z800
N0099
N0100
G14
N0101
G00
X800
Z800
N0102
X3
Z9
N0150
G01
X4
Z4
N0200
G00
X800
Z800
N0201
P10
M412S120T0101
P20
M03
P30
F0.4
P40
M05
P10
M41S120T0101
P20
M03
P30
F0.3
P40
M05
5238-E P-259
P10 in N0001 and in N0101 synchronizes
execution of M41 S120 in those blocks.
P20 in N0002 and in N0102 synchronizes
execution of M03.
P30 in N0050 and in N0150 synchronizes
the start of cutting.
P40 in N0090 and in N0201 synchronizes
execution of M05.