(40) SP Timing Belt replacement
Removal
1. Remove the upper cover.
2. Remove the printer mechanism assembly.
3. Remove the carriage unit.
4. Remove the belt clamp.
5. Remove the timing belt.
Installation
1. Install by reverse order
2. The following adjustments are required:
- Print head gap adjustment (for upper angle)
- Card guide position adjustment
- TOF sensor's voltage adjustment
- Vertical Alignment (V-ALMNT) adjustment
- Top-of-forms adjustment (factory use)
- Skew detection value adjustment
Figure 4.57 SP Timing Belt replacement
Belt Clamp
Belt
Belt Clamp
83
Difference of teeth position shall be
less than 1 teeth.