Table B–9: MODBUS MEMORY MAP (Sheet 42 of 46)
ADDR
REGISTER NAME
D826
Clear Breaker 2 Arcing Current operand
D82B
Clear Demand operand
D82D
Clear Energy operand
D82E
Clear Hi-Z Records operand
D82F
Clear Unauthorized Access operand
D831
Clear Platform Direct Input/Output Statistics operand
D833
Reserved (13 items)
Force Contact Inputs (Read/Write Setting)
D8B0
Force Contact Input x State (96 items)
Force Contact Outputs (Read/Write Setting)
D910
Force Contact Output x State (64 items)
Direct Inputs/Outputs (Read/Write Setting)
DB40
Direct Device ID
DB41
Direct I/O Channel 1 Ring Configuration Function
DB42
Platform Direct I/O Data Rate
DB43
Direct I/O Channel 2 Ring Configuration Function
DB44
Platform Direct I/O Crossover Function
Direct input/output commands (Read/Write Command)
DB48
Direct input/output clear counters command
Direct inputs (Read/Write Setting) (96 modules)
DB50
Direct Input 1 Device Number
DB51
Direct Input 1 Number
DB52
Direct Input 1 Default State
DB53
Direct Input 1 Events
DB54
...Repeated for Direct Input 2
DB58
...Repeated for Direct Input 3
DB5C
...Repeated for Direct Input 4
DB60
...Repeated for Direct Input 5
DB64
...Repeated for Direct Input 6
DB68
...Repeated for Direct Input 7
DB6C
...Repeated for Direct Input 8
DB70
...Repeated for Direct Input 9
DB74
...Repeated for Direct Input 10
DB78
...Repeated for Direct Input 11
DB7C
...Repeated for Direct Input 12
DB80
...Repeated for Direct Input 13
DB84
...Repeated for Direct Input 14
DB88
...Repeated for Direct Input 15
DB8C
...Repeated for Direct Input 16
DB90
...Repeated for Direct Input 17
DB94
...Repeated for Direct Input 18
DB98
...Repeated for Direct Input 19
DB9C
...Repeated for Direct Input 20
DBA0
...Repeated for Direct Input 21
DBA4
...Repeated for Direct Input 22
DBA8
...Repeated for Direct Input 23
DBAC
...Repeated for Direct Input 24
DBB0
...Repeated for Direct Input 25
DBB4
...Repeated for Direct Input 26
DBB8
...Repeated for Direct Input 27
DBBC
...Repeated for Direct Input 28
DBC0
...Repeated for Direct Input 29
DBC4
...Repeated for Direct Input 30
DBC8
...Repeated for Direct Input 31
GE Multilin
RANGE
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
---
0 to 2
0 to 3
1 to 16
0 to 1
64 to 128
0 to 1
0 to 1
0 to 1
0 to 16
0 to 96
0 to 3
0 to 1
F60 Feeder Management Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
---
F001
---
1
F144
---
1
F131
---
1
F001
---
1
F126
kbps
64
F001
---
1
F126
---
1
F102
---
1
F126
---
1
F001
---
1
F001
---
1
F086
---
1
F102
DEFAULT
0
0
0
0
0
B
0
0
0 (Disabled)
0 (Disabled)
1
0 (No)
64
0 (No)
0 (Disabled)
0 (No)
0
0
0 (Off)
0 (Disabled)