5 SETTINGS
Table 5–6: F60 FLEXLOGIC™ OPERANDS (Sheet 2 of 6)
OPERAND TYPE
OPERAND SYNTAX
ELEMENT:
BREAKER 1 OFF CMD
Breaker Control
BREAKER 1 ON CMD
BREAKER 1 φA CLSD
BREAKER 1 φB CLSD
BREAKER 1 φC CLSD
BREAKER 1 CLOSED
BREAKER 1 OPEN
BREAKER 1 DISCREP
BREAKER 1 TROUBLE
BREAKER 1 MNL CLS
BREAKER 1 TRIP A
BREAKER 1 TRIP B
BREAKER 1 TRIP C
BREAKER 1 ANY P OPEN
BREAKER 1 ONE P OPEN
BREAKER 1 OOS
BREAKER 2
ELEMENT
COLD LOAD 1 OP
Cold Load Pickup
COLD LOAD 2 OP
ELEMENT:
Counter 1 HI
Digital Counters
Counter 1 EQL
Counter 1 LO
Counter 8 HI
Counter 8 EQL
Counter 8 LO
ELEMENT:
Dig Element 1 PKP
Digital Elements
Dig Element 1 OP
Dig Element 1 DPO
Dig Element 48 PKP
Dig Element 48 OP
Dig Element 48 DPO
ELEMENT:
DIR POWER 1 STG1 PKP
Sensitive Directional
DIR POWER 1 STG2 PKP
Power
DIR POWER 1 STG1 DPO
DIR POWER 1 STG2 DPO
DIR POWER 1 STG1 OP
DIR POWER 1 STG2 OP
DIR POWER 1 PKP
DIR POWER 1 DPO
DIR POWER 1 OP
DIR POWER 2
ELEMENT
FREQ RATE n PKP
Frequency Rate of
FREQ RATE n DPO
Change
FREQ RATE n OP
ELEMENT:
FxE 1 PKP
FlexElements™
FxE 1 OP
FxE 1 DPO
FxE 8 PKP
FxE 8 OP
FxE 8 DPO
ELEMENT:
GROUND IOC1 PKP
Ground
GROUND IOC1 OP
Instantaneous
GROUND IOC1 DPO
Overcurrent
GROUND IOC2
ELEMENT:
GROUND TOC1 PKP
Ground Time
GROUND TOC1 OP
Overcurrent
GROUND TOC1 DPO
GROUND TOC2
GE Multilin
OPERAND DESCRIPTION
Breaker 1 OFF command
Breaker 1 ON command
Breaker 1 phase A is closed
Breaker 1 phase B is closed
Breaker 1 phase C is closed
Breaker 1 is closed
Breaker 1 is open
Breaker 1 has discrepancy
Breaker 1 trouble alarm
Breaker 1 manual close
Breaker 1 trip phase A command
Breaker 1 trip phase B command
Breaker 1 trip phase C command
At least one pole of Breaker 1 is open
Only one pole of Breaker 1 is open
Breaker 1 is out of service
Same set of operands as shown for BREAKER 1
Cold Load Pickup element 1 has operated
Cold Load Pickup element 2 has operated
Digital Counter 1 output is 'more than' comparison value
Digital Counter 1 output is 'equal to' comparison value
Digital Counter 1 output is 'less than' comparison value
Digital Counter 8 output is 'more than' comparison value
Digital Counter 8 output is 'equal to' comparison value
Digital Counter 8 output is 'less than' comparison value
Digital Element 1 is picked up
Digital Element 1 is operated
Digital Element 1 is dropped out
Digital Element 48 is picked up
Digital Element 48 is operated
Digital Element 48 is dropped out
Stage 1 of the Directional Power element 1 has picked up
Stage 2 of the Directional Power element 1 has picked up
Stage 1 of the Directional Power element 1 has dropped out
Stage 2 of the Directional Power element 1 has dropped out
Stage 1 of the Directional Power element 1 has operated
Stage 2 of the Directional Power element 1 has operated
The Directional Power element has picked up
The Directional Power element has dropped out
The Directional Power element has operated
Same set of operands as DIR POWER 1
The n-th Frequency Rate of Change element has picked up
The n-th Frequency Rate of Change element has dropped out
The n-th Frequency Rate of Change element has operated
FlexElement™ 1 has picked up
FlexElement™ 1 has operated
FlexElement™ 1 has dropped out
FlexElement™ 8 has picked up
FlexElement™ 8 has operated
FlexElement™ 8 has dropped out
Ground Instantaneous Overcurrent 1 has picked up
Ground Instantaneous Overcurrent 1 has operated
Ground Instantaneous Overcurrent 1 has dropped out
Same set of operands as shown for GROUND IOC 1
Ground Time Overcurrent 1 has picked up
Ground Time Overcurrent 1 has operated
Ground Time Overcurrent 1 has dropped out
Same set of operands as shown for GROUND TOC1
F60 Feeder Management Relay
5.4 FLEXLOGIC™