GE F60 Instruction Manual page 347

Ur series
Hide thumbs Also See for F60:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 26 of 46)
ADDR
REGISTER NAME
7830
...Repeated for RTD Input 48
High Impedance Fault Detection (Hi-Z) Settings (Read/Write Setting)
7A00
Hi-Z Function
7A01
Hi-Z Signal Source
7A03
Hi-Z Arcing Sensitivity
7A04
Hi-Z Phase Event Count
7A05
Hi-Z Ground Event Count
7A06
Hi-Z Event Count Time
7A07
Hi-Z Overcurrent Protection Coordination Timeout
7A08
Hi-Z Phase Overcurrent Minimum Pickup
7A09
Hi-Z Neutral Overcurrent Minimum Pickup
7A0A
Hi-Z Phase Rate of Change
7A0B
Hi-Z Neutral Rate of Change
7A0C
Hi-Z Loss of Load Threshold
7A0D
Hi-Z 3-Phase Event Threshold
7A0E
Hi-Z Voltage Supervision Threshold
7A0F
Hi-Z Voltage Supervision Delay
7A10
HIZ Even Harmonic Restraint
7A11
Hi-Z Target
7A12
Hi-Z Events
Underfrequency (Read/Write Setting) (6 modules)
7E00
Underfrequency Function
7E01
Underfrequency 1 Block
7E02
Underfrequency 1 Minimum Current
7E03
Underfrequency 1 Pickup
7E04
Underfrequency 1 Pickup Delay
7E05
Underfrequency 1 Reset Delay
7E06
Underfrequency 1 Source
7E07
Underfrequency 1 Events
7E08
Underfrequency 1 Target
7E09
Reserved (8 items)
7E11
...Repeated for Underfrequency 2
7E22
...Repeated for Underfrequency 3
7E33
...Repeated for Underfrequency 4
7E44
...Repeated for Underfrequency 5
7E55
...Repeated for Underfrequency 6
Neutral Overvoltage (Read/Write Grouped Setting) (3 modules)
7F00
Neutral Overvoltage 1 Function
7F01
Neutral Overvoltage 1 Signal Source
7F02
Neutral Overvoltage 1 Pickup
7F03
Neutral Overvoltage 1 Pickup Delay
7F04
Neutral Overvoltage 1 Reset Delay
7F05
Neutral Overvoltage 1 Block
7F06
Neutral Overvoltage 1 Target
7F07
Neutral Overvoltage 1 Events
7F08
Reserved (8 items)
7F10
...Repeated for Neutral Overvoltage 2
7F20
...Repeated for Neutral Overvoltage 3
Auxiliary Overvoltage (Read/Write Grouped Setting) (3 modules)
7F30
Auxiliary Overvoltage 1 Function
7F31
Auxiliary Overvoltage 1 Signal Source
7F32
Auxiliary Overvoltage 1 Pickup
7F33
Auxiliary Overvoltage 1 Pickup Delay
7F34
Auxiliary Overvoltage 1 Reset Delay
GE Multilin
RANGE
0 to 1
0 to 5
1 to 10
10 to 250
10 to 500
5 to 180
10 to 200
0.01 to 10
0.01 to 10
1 to 999
1 to 999
5 to 100
1 to 1000
0 to 100
0 to 300
0 to 100
0 to 2
0 to 1
0 to 1
0 to 65535
0.1 to 1.25
20 to 65
0 to 65.535
0 to 65.535
0 to 5
0 to 1
0 to 2
0 to 1
0 to 1
0 to 5
0 to 1.25
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 65535
0 to 1
0 to 5
0 to 3
0 to 600
0 to 600
F60 Feeder Management Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F102
---
1
F167
---
1
F001
---
1
F001
---
1
F001
min
1
F001
s
1
F001
pu
0.01
F001
pu
0.01
F001
A/2cycle
1
F001
A/2cycle
1
F001
%
1
F001
A
1
F001
%
1
F001
cycles
2
F001
%
1
F001
---
1
F109
---
1
F102
---
1
F102
---
1
F300
pu
0.01
F001
Hz
0.01
F001
s
0.001
F001
s
0.001
F001
---
1
F167
---
1
F102
---
1
F109
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
DEFAULT
0 (Disabled)
0 (SRC 1)
5
B
30
30
15
15
150
100
150
150
15
25
5
60
20
0 (Self-reset)
0 (Disabled)
0 (Disabled)
0
10
5950
2000
2000
0 (SRC 1)
0 (Disabled)
0 (Self-reset)
0
0 (Disabled)
0 (SRC 1)
300
100
100
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
300
100
100
B-33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents