B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 17 of 46)
ADDR
REGISTER NAME
4E21
User Programmable Pushbutton 1 Events
4E22
User Programmable Pushbutton 1 Reserved (2 items)
4E24
...Repeated for User Programmable Pushbutton 2
4E48
...Repeated for User Programmable Pushbutton 3
4E6C
...Repeated for User Programmable Pushbutton 4
B
4E90
...Repeated for User Programmable Pushbutton 5
4EB4
...Repeated for User Programmable Pushbutton 6
4ED8
...Repeated for User Programmable Pushbutton 7
4EFC
...Repeated for User Programmable Pushbutton 8
4F20
...Repeated for User Programmable Pushbutton 9
4F44
...Repeated for User Programmable Pushbutton 10
4F68
...Repeated for User Programmable Pushbutton 11
4F8C
...Repeated for User Programmable Pushbutton 12
Flexlogic (Read/Write Setting)
5000
FlexLogic™ Entry (512 items)
Flexlogic Timers (Read/Write Setting) (32 modules)
5800
FlexLogic™ Timer 1 Type
5801
FlexLogic™ Timer 1 Pickup Delay
5802
FlexLogic™ Timer 1 Dropout Delay
5803
Reserved (5 items)
5808
...Repeated for FlexLogic™ Timer 2
5810
...Repeated for FlexLogic™ Timer 3
5818
...Repeated for FlexLogic™ Timer 4
5820
...Repeated for FlexLogic™ Timer 5
5828
...Repeated for FlexLogic™ Timer 6
5830
...Repeated for FlexLogic™ Timer 7
5838
...Repeated for FlexLogic™ Timer 8
5840
...Repeated for FlexLogic™ Timer 9
5848
...Repeated for FlexLogic™ Timer 10
5850
...Repeated for FlexLogic™ Timer 11
5858
...Repeated for FlexLogic™ Timer 12
5860
...Repeated for FlexLogic™ Timer 13
5868
...Repeated for FlexLogic™ Timer 14
5870
...Repeated for FlexLogic™ Timer 15
5878
...Repeated for FlexLogic™ Timer 16
5880
...Repeated for FlexLogic™ Timer 17
5888
...Repeated for FlexLogic™ Timer 18
5890
...Repeated for FlexLogic™ Timer 19
5898
...Repeated for FlexLogic™ Timer 20
58A0
...Repeated for FlexLogic™ Timer 21
58A8
...Repeated for FlexLogic™ Timer 22
58B0
...Repeated for FlexLogic™ Timer 23
58B8
...Repeated for FlexLogic™ Timer 24
58C0
...Repeated for FlexLogic™ Timer 25
58C8
...Repeated for FlexLogic™ Timer 26
58D0
...Repeated for FlexLogic™ Timer 27
58D8
...Repeated for FlexLogic™ Timer 28
58E0
...Repeated for FlexLogic™ Timer 29
58E8
...Repeated for FlexLogic™ Timer 30
58F0
...Repeated for FlexLogic™ Timer 31
58F8
...Repeated for FlexLogic™ Timer 32
Phase Time Overcurrent (Read/Write Grouped Setting) (6 modules)
5900
Phase Time Overcurrent 1 Function
5901
Phase Time Overcurrent 1 Signal Source
B-24
RANGE
0 to 1
0 to 65535
0 to 65535
0 to 2
0 to 60000
0 to 60000
0 to 65535
0 to 1
0 to 5
F60 Feeder Management Relay
APPENDIX B
UNITS
STEP
FORMAT
---
1
F102
---
1
F001
---
1
F300
---
1
F129
---
1
F001
---
1
F001
---
1
F001
---
1
F102
---
1
F167
DEFAULT
0 (Disabled)
0
16384
0 (millisecond)
0
0
0
0 (Disabled)
0 (SRC 1)
GE Multilin

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents