● DSCP codes 32 - 47 → Queue 3
● DSCP codes 48 - 63 → Queue 4
Steps in configuration
1. For each value in the "DSCP" column, select the forwarding queue from the "Queue"
drop-down list.
2. Click the "Set Values" button.
5.5.3

Rate control

Limiting the transfer rate of incoming and outgoing data
On this page, you configure the load limitation (maximum number of data packets per
second) for the individual ports. You can specify the category of frame for which these limit
values will apply.
Description of the displayed values
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports.
● Limit Ingress Unicast (DLF) / Limit Ingress Broadcast / Limit Ingress Multicast
Select the required setting in the drop-down list.
– enabled: Enables the function.
– disabled: Disables the function
– No Change: The setting in table 2 remains unchanged
SCALANCE XB-200 Web Based Management
Configuration Manual, 04/2015, C79000-G8976-C360-02
Configuring with Web Based Management
5.5 The "Layer 2" menu
131