Port Diagnostics; Cable Tester - Siemens SCALANCE XB-200 Web Based Management

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XB-200:
Table of Contents

Advertisement

Configuring with Web Based Management
5.4 The "System" menu
5.4.19

Port Diagnostics

5.4.19.1

Cable tester

With this page, each individual Ethernet port can run independent fault diagnostics on the
cable. This test is performed without needing to remove the cable, connect a cable tester
and install a loopback module at the other end. Short-circuits and cable breaks can be
localized to within a few meters.
Note
Please note that this test is permitted only when no data connection is established on the
port to be tested.
If, however, there is a data connection to the port to be tested, this is briefly interrupted.
Automatic re-establishment of the connection can fail and then needs to be done manually.
Description
The page contains the following boxes:
● Port
Select the required port from the drop-down list.
● Run Test
Activates error diagnostics. The result is shown in the table.
124
SCALANCE XB-200 Web Based Management
Configuration Manual, 04/2015, C79000-G8976-C360-02