Advertisement

Description
The page contains the following boxes:
● Time Manually
Enable or disable manual setting of the time. If you enable the option, the "System Time"
input box can be edited.
● System Time
Enter the date and time in the format "MM/DD/YYYY HH:MM:SS".
After a restart, the time of day begins at 01/01/2000 00:00:00
● Use PC Time
Click the button to use the time setting of the PC.
● Last Synchronization Time
This box is read-only and shows when the last time-of-day synchronization took place. If
no time-of-day synchronization was possible, the box displays "Date/time not set".
● Last Synchronization Mechanism
This box displays how the last time-of-day synchronization was performed.
– Not set
– Manual
– SNTP
– NTP
– SIMATIC
Procedure
1. Enable the "Time Manually" option.
2. Click in the "System Time" input box.
3. In the "System Time" input box, enter the date and time in the format "MM/DD/YYYY
HH:MM:SS".
4. Click the "Set Values" button.
The date and time are adopted and "Manual" is entered in the "Last Synchronization
Mechanism" box.
SCALANCE XB-200 Web Based Management
Configuration Manual, 04/2015, C79000-G8976-C360-02
The system time was not set.
Manual time setting
Automatic time-of-day synchronization with SNTP
Automatic time-of-day synchronization with NTP
Automatic time-of-day synchronization using the SIMATIC time frame
Configuring with Web Based Management
5.4 The "System" menu
101