Advertisement

Mechanical Disassembly

13-1 AC inlet assy disassembly

1 Remove the line filter cover. Remove 2 screws-A (M4x6) and remove the AC inlet
cover.
2 Remove the line filter board by unhooking 3 hooks.
3 Remove 2 screws-B(M3x10) and remove the AC inlet.
4 Pull the AC switch (SW901) out backward.
5 Remove 2 screws-C(M4x16) and remove the lamp cover switch (SW902).
6 Remove fuse holder.

13-2 Wiring of the AC inlet assy

See the following figures for wiring.
Fuse holder
a
a
Line filter cover
From Power(AC)
Board "K6A"
Fuse holder
Brown
SW902
Line filter board
Insulation sheet
AC inlet cover
Blue
-37-
c
c
Inlet holder
B
B
SW901
AC inlet