Electrical Adjustment
Grp / No. Item
6 Position Check Time
7 Stop Mode
8 Enable Close Cmd
9 Speed Control
10 Shutter Management Upper Time
239
Illumance Sensor
0 Illuminance Factory Data
1 Illuminance Factory Data
2 Illuminance Factory Data
3 Illuminance Factory Data
4 Illuminance Model Data
5 Illuminance Model Data
6 Illuminance Model Data
7 Illuminance Model Data
-
10 Illuminance Factory Data
11 Illuminance Factory Data
12 Illuminance Factory Data
13 Illuminance Factory Data
14 Illuminance Model Data
15 Illuminance Model Data
16 Illuminance Model Data
17 Illuminance Model Data
-
20 Illuminance Factory Data
21 Illuminance Factory Data
22 Illuminance Factory Data
23 Illuminance Factory Data
24 Illuminance Model Data
25 Illuminance Model Data
26 Illuminance Model Data
27 Illuminance Model Data
240
Flow Calibration
0 Flow Calibration Exe
1 Flow Calibration Error Log
2 Clog Check Enable
3 Air Inlet Check Enable
4 Time Limit Auto Scroll Enable
5 Clog Auto Cooling Enable
6 Scroll Fail Auto Cooling Enable
7 Time Force Scroll Enable
241
Flow Ideal Data
0 Flow Ideal Data 1
1 Flow Ideal Data 2
2 Flow Ideal Data 3
3 Flow Ideal Data 4
4 Flow Ideal Data 5
5 Flow Ideal Data 6
6 Flow Ideal Data 7
7 Flow Ideal Data 8
242
Flow Calib. Fan Volt
0 Flow Calib Fan Volt 1
1 Flow Calib Fan Volt 2
2 Flow Calib Fan Volt 3
3 Flow Calib Fan Volt 4
4 Flow Calib Fan Volt 5
5 Flow Calib Fan Volt 6
Function
Position Check Time
Shutter Operation in Stop Mode
0:Free, 1:Brake
Shutter Close Command
0:Disable, 1:Enable
Flow Sensor Offset Calibration Start calibration when the value is
set to 1.
Log of Calibration Error (Read only)
255: Not Calibration
0: No Error
10: 1st Calibration Not Stable Airflow
11: 1st Calibration Out of Range
20: 2nd Not Stable Airflow
21: 2nd Out of Range
100: 10th Calibration Not Stable Airflow
101: 10th Calibration Out of Range
Filter Clogged Detection by Flow Sensor (0: Disable, 1: Enable)
Intake Vent Error Check (0: Disable, 1: Enable)
(0: Disable, 1: Enable)
Cooling on Clog (0: Disable, 1: Enable)
Coolin on Scroll error (0: Disable, 1: Enable)
Forced Scroll on Filter Timer Reached (0: Disable, 1: Enable)
(Value will be set after calibration)
Flow Sensor Theory Value No.1 Corresponding to Fan Volt No.1
Flow Sensor Theory Value No.2 Corresponding to Fan Volt No.2
Flow Sensor Theory Value No.3 Corresponding to Fan Volt No.3
Flow Sensor Theory Value No.4 Corresponding to Fan Volt No.4
Flow Sensor Theory Value No.5 Corresponding to Fan Volt No.5
Flow Sensor Theory Value No.6 Corresponding to Fan Volt No.6
Flow Sensor Theory Value No.7 Corresponding to Fan Volt No.7
Flow Sensor Theory Value No.8 Corresponding to Fan Volt No.8
(Not Memorized)
Flow Sensor Calibration Fan Volt No.1 [V x10]
Flow Sensor Calibration Fan Volt No.2 [V x10]
Flow Sensor Calibration Fan Volt No.3 [V x10]
Flow Sensor Calibration Fan Volt No.4 [V x10]
Flow Sensor Calibration Fan Volt No.5 [V x10]
Flow Sensor Calibration Fan Volt No.6 [V x10]
Range
1 - 255
0 - 1
0 - 1
0 - 255
180 - 999
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 1
-
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
-82-
Initial
Note
30
0
1
0
480
10000
8300
7500
6250
5281
5138
3891
3806
5000
4150
3750
3125
2585
2569
1882
1895
5000
4150
3750
3125
2655
2586
1938
1904
0
255
Initial: 0 / Shipping: 1
Initial: 0 / Shipping: 1
1
1
1
0
290
325
350
375
390
1023
1023
1023
50*
75
100
115
132*
255