Electrical Adjustment
Grp / No. Item
0 Fan 1 Min Adjust (DAC)
1 Fan 1 Max Adjust (DAC)
2 Fan 2 Min Adjust (DAC)
3 Fan 2 Max Adjust (DAC)
4 Fan 3 Min Adjust (DAC)
5 Fan 3 Max Adjust (DAC)
6 Fan 4 Min Adjust (DAC)
7 Fan 4 Max Adjust (DAC)
8 Fan 5 Miin Adjust (DAC)
9 Fan 5 Max Adjust (DAC)
10 Fan 5 Miin Adjust (DAC)
11 Fan 5 Max Adjust (DAC)
252
Fan Option
1 Safety Switch
2 Fan Manual Switch
3 Fan 1 Manual Voltage
4 Fan 2 Manual Voltage
5 Fan 3 Manual Voltage
6 Fan 4 Manual Voltage
7 Fan 5 Manual Voltage
8 Fan 6 Manual Voltage
253
Fan Temp Error Setting
0 Temp A Warning
1 Temp C-A Warnin
254
Fan Control Range Setting
0 Normal Fan Control Min Temp
1 Normal Fan Control Max Temp
2 Normal Fan 1 Min
3 Normal Fan 1 Max
4 Normal Fan 2 Min
5 Normal Fan 2 Max
6 Normal Fan 3 Min
7 Normal Fan 3 Max
8 Normal Fan 4 Min
9 Normal Fan 4 Max
10 Normal Fan 5 Min
11 Normal Fan 5 Max
12 Normal Fan 6 Min
13 Normal Fan 6 Max
14 Eco Fan Control Min Temp
15 Eco Fan Control Max Temp
16 Eco Fan 1 Min
17 Eco Fan 1 Max
18 Eco Fan 2 Min
19 Eco Fan 2 Max
20 Eco Fan 3 Min
21 Eco Fan 3 Max
22 Eco Fan 4 Min
23 Eco Fan 4 Max
24 Eco Fan 5 Min
25 Eco Fan 5 Max
26 Eco Fan 6 Min
27 Eco Fan 6 Max
255
Fan Start/Cooling Setting
0 Fan 1 Initial Volt
1 Fan 2 Initial Volt
2 Fan 3 Initial Volt
3 Fan 4 Initial Volt
4 Fan 5 Initial Volt
5 Fan 6 Inital Volt
6 Cooling Time
8 Temp Error Cooling Time
9 OnStart Cooling Start Threshold
10 After shutdown cooling
Function
DAC Output for Fan Voltage adj.
Adjust Tolerance between DAC and Fan Volt.
*Lamp Mode: Eco
Safety Application use
Fan Manual SW (0: Auto 1: Manual)
Manual Adjustment Mode (0.1V)
*Effective only when Manual SW is 1.
(Memorized)
Temp A (Room) to judge the Temp Error
Temp C-A (Panel - Room) to judge the Temp Error
(Temp/Voltage)
Temp Sensor Control Start/End Temp at Normal
Fan Voltage Set at Normal (Min/Max) (x0.1V)
Temp Sensor Control Start/End Temp at Eco
Fan Voltage Set at Eco (Min/Max) (x0.1V)
Fan Start Voltage (x0.1V)
Cooling Time Setting (x30 sec.) 1: 30 3: 90 15: 450
Cooling Time Setting When the Temp Error occurs (x30 sec.)
1: 30 3: 90 15: 450
Cooling Operation after Shut Down (0: No, 1: Yes)
Range
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 8
0 - 1
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
-
Normal
30 - 100
44
0 - 100
20
Normal
20 - 100
27
20 - 100
42
0 - 255
60
0 - 255
132
0 - 255
85
0 - 255
135
0 - 255
80
0 - 255
132
0 - 255
115
0 - 255
115
0 - 255
115
0 - 255
115
0 - 255
70
0 - 255
132
20 - 100
27
20 - 100
42
0 - 255
50
0 - 255
120
0 - 255
55
0 - 255
125
0 - 255
70
0 - 255
125
0 - 255
80
0 - 255
80
0 - 255
80
0 - 255
80
0 - 255
55
0 - 255
125
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
1-15
1-15
0-100
0-1
-85-
Initial
Note
39
212
50
218
82
213
64
211
65
211
28
211
0
0
100
100
100
100
100
100
-
Ceiling
Top
Bottom
44
44
44
20
20
20
Ceiling
Top
Bottom
27
27
27
42
42
42
60
60
60
132
132
132
85
85
85
135
135
135
80
80
80
132
132
132
115
105
105
115
105
105
115
105
105
115
105
105
70
70
70
132
132
132
27
27
27
42
42
42
50
50
50
120
120
120
55
55
55
125
125
125
70
70
70
125
125
125
80
70
70
80
70
70
80
70
70
80
70
70
55
55
55
125
125
125
50
75
70
80
80
55
3
3
38
1