3.3.d Plumbing Requirements
CAUTION - Failure to heed the following may result in equipment damage.
Do not use glue on the threaded portion of the equipment's unions. A glued-in-place union will prevent the
l
equipment from being properly winterized.
The heat pump must receive water flow within the specified minimum ranges under worst-case conditions such
l
as a fouled water filter.
Water flow exceeding maximum flow rates may damage heat pump and will not be covered under equipment
l
warranty. See "Water Flow Rates" on page 6.
Install a bypass valve whenever water-flow may exceed maximum rating.
l
See "5 lb Bypass Valve Kit (Kit STK0135)" on page 40.
l
For additional guidance testing water flow rates, please contact AquaCal
l
3.3.e Plumbing Diagrams
Plumbing diagrams are provided in this section as a planning guide to the sequence of equipment, valves,
and fittings.
The basic plumbing configurations for typical installations are shown.
l
If the installation does not closely follow any of the supplied plumbing diagrams, AquaCal
l
available for installation advice and guidance.
Air Source Heat Pump Plumbing Diagrams
Heat Pump with water flows equal or less than maximum listed flow rate
See "Water Flow Rates" on page 6.
Page - 9
®
Technical Support.
®
Technical Support is