Aquacal HeatWave SuperQuiet SQ120R Installation Manual page 11

Up to 70gpm flow rate
Hide thumbs Also See for HeatWave SuperQuiet SQ120R:
Table of Contents

Advertisement

1. Adjust heat pump thermostat to its lowest setting while in
HEA mode.
2. Deactivate the water filtration pump.
3. Adjust valves to a halfway open position leading to the
heat pump.
4. Adjust valves to a fully open position leading away from
the heat pump.
5. Activate the pool water filtration pump.
6. Slowly turn the thermostat up until the heat pump
activates.
After a four-minute delay, the heat pump
l
compressor will start.
7. With the heat pump running, confirm water filtration
pump is operating properly with adequate flow and no
short cycling. If needed, clean filters leading to the heat pump.
8. Wait for water and refrigerant pressure to stabilize (approximately 5 minutes).
9. Adjust valves in the following order:
A. Adjust valve leading away from the heat pump to correct temperatures measured with a temperature
pressure probe.
B. Allow pressure to stabilize . Then check temperature again. Re-adjust valve leading away from the
heat pump as needed.
10. Mark valves at these positions for future reference.
Temperature differences are based on pool temperatures of 72° (+ or – 3° F). For water
temperatures outside this range, contact AquaCal
MODEL
SQ120R
SQ125
SQ145
SQ166R
SQ225
T035
T055
T075
T090
T115
T135
Table 1 - Temperature Chart
®
Technical Support.
TEMPERATURE
3° to 7° F
3° to 7° F
3° to 7° F
3° to 8° F
4° to 9° F
1° to 4° F
2° to 5° F
3° to 7° F
3° to 6° F
3° to 7° F
4° to 8° F
Temperature / Pressure Port
(Shown with Probe)
Page - 8