SECTION 2 - INSTALLATION
For commercial or complete installation instructions please, visit www.AquaCal.com for equipment manual.
EQUIPMENT CLEARANCES
Keep the area to the front and immediately adjacent to the heat pump clear of items such as shrubs and bushes,
lawn furniture, chemicals containers, etc. These items can prevent air from circulating properly through the heater,
and will result in inefficient operation and/or damage to the heat pump.
1" Clearance Overhead
(Front)
60"
Minimimum
Rain Run-Off and Sprinklers Should Be Directed
Away From Heater
PLUMBING SCHEMATIC
F
H
B
um Clearance
ELECTRICAL REQUIREMENTS
Locate the equipment power disconnect within 6-feet of the heater's electrical enclosure.
1)
2)
Never mount power disconnects directly to heat pump.
3)
Only use copper conductors.
4)
Use optional sequencing controllers when multiple heaters are installed on site.
5)
Local codes and regulations may require the use of a ground fault interruption device (GFI Circuit Breaker).
Nuisance tripping of these devices is common and not covered under the terms of the Manufacturer's warranty.
6)
Review online product manual when connecting external controller devices to heat pump.
(Rear and Sides)
12" Clearance