Chart Set Up Group; Table 3-5 Chart Group Function Prompts - Honeywell DR4500A Product Manual

Classic series circular chart recorder with or without control
Hide thumbs Also See for DR4500A:
Table of Contents

Advertisement

3.8 Chart Set Up Group

Introduction
The functions listed in this group deal with the parameters that must be set to assure proper chart function.
CAUTION
Before making any configuration changes to the Chart Set Up group, place the recorder in
"Chart Hold". Press the CHART key to stop the chart rotation. Press again after configuration
entry is made.
Function prompts
Table 3-5 lists all the function prompts in the "Chart" Set Up group.
Function Prompt
Lower Display
CHRTSPD
Chart Speed Selection
HOUR/REV
Hours per Revolution
(appears only if "XHR" is
selected above)
LINEARIZ
Linearization
Release M
DR4500A Classic Series Circular Chart Recorder With or Without Control Product Manual
April 2017

Table 3-5 Chart group function prompts

Function Name
Selections or Range of Setting
Upper Display
8HR
12HR
24HR
7DAYS
XHR (See prompt "HOUR/REV")
1 to 744
LINEAR
NONLIN
Configuration
Chart Set Up Group
Factory
Setting
XHR
12
––
65