1-5.
Settings and starting of DIP switch and UNIT ID switch
* Turn off the power when setting the DIP switch.
If the power is turned on, no setting will be reflected.
• Make settings for the DIP switch and UNIT ID switch of RSio64-D (Subject to test).
1) DIP switch is set as diagnostic mode.
Dip Switch 3, 7, 8 g on , Others g off
2) ID switch is set as 2.
3) Power switch of RSio64-D is turned on.
• Make settings for the DIP switch and UNIT ID switch of RSio64-D (Set to test jig mode).
1) DIP switch is set as diagnostic mode.
Dip Switch 3, 7, 8 g on , Others g off
2) ID switch is set as B (Test jig mode).
3) Power switch of RSio64-D is turned on.
It checks having started in diagnostic mode because green LEDs all lighting.
The LED circuit has broken when green LEDs do not all lighting.