Product View - ABB DCS 600 Manual

Dcs thyristor power converters for dc drive systems 25 to 5150 a 6 to 4900 kw
Hide thumbs Also See for DCS 600:
Table of Contents

Advertisement

Construction type C1
Converter type
Dimensions
H x W x D
1 2 3 4 5 6 7 8 9 0 1 2 3
1 2 3 4 5 6 7 8 9 0 1 2 3
DCS60x-0025-y1
420x273x195
1 2 3 4 5 6 7 8 9 0 1 2 3
1 2 3 4 5 6 7 8 9 0 1 2 3
DCS60x-0050-y1
420x273x195
1 2 3 4 5 6 7 8 9 0 1 2 3
1 2 3 4 5 6 7 8 9 0 1 2 3
DCS60x-0050-61
420x273x195
1 2 3 4 5 6 7 8 9 0 1 2 3
DCS60x-0075-y1
420x273x195
1 2 3 4 5 6 7 8 9 0 1 2 3
1 2 3 4 5 6 7 8 9 0 1 2 3
DCS60x-0100-y1
469x273x228
1 2 3 4 5 6 7 8 9 0 1 2 3
1 2 3 4 5 6 7 8 9 0 1 2 3
DCS60x-0110-61
469x273x228
1 2 3 4 5 6 7 8 9 0 1 2 3
DCS60x-0140-y1
469x273x228
1 2 3 4 5 6 7 8 9 0 1 2 3
1 2 3 4 5 6 7 8 9 0 1 2 3
1 2 3 4 5 6 7 8 9 0 1 2 3
DCS60x-0200-y1
505x273x361
DCS60x-0250-y1
505x273x361
1 2 3 4 5 6 7 8 9 0 1 2 3
1 2 3 4 5 6 7 8 9 0 1 2 3
DCS60x-0270-61
505x273x361
1 2 3 4 5 6 7 8 9 0 1 2 3
1 2 3 4 5 6 7 8 9 0 1 2 3
DCS60x-0350-y1
505x273x361
1 2 3 4 5 6 7 8 9 0 1 2 3
1 2 3 4 5 6 7 8 9 0 1 2 3
DCS60x-0450-y1
505x273x361
1 2 3 4 5 6 7 8 9 0 1 2 3
1 2 3 4 5 6 7 8 9 0 1 2 3
DCS60x-0520-y1
505x273x361
1 2 3 4 5 6 7 8 9 0 1 2 3
DCS60x-0700-y1
652x273x384
DCS60x-0900-y1
1493x548x447
DCS60x-1200-y1
1493x548x447
DCS60x-1500-y1
1493x548x447
DCS60x-2000-y1
1493x548x447
DCS60x-2050-y1
2330x820x624
DCS60x-2500-y1
2330x820x624
DCS60x-2650-y1
2330x820x624
DCS60x-3200-y1
2330x820x624
DCS60x-3300-y1
2330x820x624
DCS60x-4000-y1
2330x820x624
DCS60x-4750-y1
2330x820x624
DCS60x-5150-y1
2330x820x624
The dimensions for modules with busbar connection on the right side are 2330x800x624 mm
(Busbar connect. on the right side is optionally, Example for the type designat.: connection left DCS60x-2050-y1; connection right DCS60x-2050+y1)
The depth of 1000 V units is 654 mm
x=1
2-Q; x=2
4-Q; y=4...9
On supply voltages up to 400 V in delta connection; from 415 V on in star connection
1 2 3 4 5
1 2 3 4 5
also available as field supply converter DCF60x (for 500 V s. also table 2.2/2). Data are the same as the armature current converter DCS60x
1 2 3 4 5
Table 2.2/3: Table of DCS 600 unit types
Construction type C2
Weight
[mm]
[kg]
7.1
7.2
7.6
7.6
11.5
11.5
11.5
22.3
22.3
22.8
22.8
28.9
28.9
57
150
150
150
150
350
350
350
350
350
350
350
350
400...1000 V supply voltage
Construction type C3
Clearances
Construct.
top/bottom/side
type
[mm]
150x100x5
C1
150x100x5
C1
150x100x5
C1
150x100x5
C1
250x150x5
C1
250x150x5
C1
250x150x5
C1
250x150x5
C2
250x150x5
C2
250x150x5
C2
250x150x5
C2
250x150x10
C2
250x150x10
C2
250x150x10
C2
300x100x20
C3
300x100x20
C3
300x100x20
C3
300x100x20
C3
C4
C4
C4
C4
to be installed
C4
in cubicle
C4
C4
C4
Construction type C4
Left busbar connection
Power loss
Fan
at 500V
connection
P
[kW]
V
< 0.2
230 V/1 ph
< 0.2
230 V/1 ph
-
230 V/1 ph
< 0.3
230 V/1 ph
< 0.5
230 V/1 ph
-
230 V/1 ph
< 0.6
230 V/1 ph
< 0.8
230 V/1 ph
< 1.0
230 V/1 ph
-
230 V/1 ph
< 1.3
230 V/1 ph
< 1.5
230 V/1 ph
< 1.8
230 V/1 ph
< 2.5
230 V/1 ph
< 4.8
400/690 V/3 ph
< 6.2
400/690 V/3 ph
< 6.3
400/690 V/3 ph
< 8.2
400/690 V/3 ph
-
400/690 V/3 ph
< 12
400/690 V/3 ph
-
400/690 V/3 ph
-
400/690 V/3 ph
< 15
400/690 V/3 ph
< 16
400/690 V/3 ph
-
400/690 V/3 ph
< 20
400/690 V/3 ph
II F 2-5
Semiconductor
Fuses
extern
extern
extern
extern
extern
extern
extern
extern
extern
extern
extern
extern
extern
extern
intern
intern
intern
intern
intern
intern
intern
intern
intern
intern
intern
intern