Main Status Word; Auxiliary Status Word; Di Status Word - ABB DCS 600 Manual

Dcs thyristor power converters for dc drive systems 25 to 5150 a 6 to 4900 kw
Hide thumbs Also See for DCS 600:
Table of Contents

Advertisement

Main Status Word (8.01)

ABB Drive Profile Control Word
Bit
Name
0
RDY_ON
1
RDY_RUN
2
RDY_REF
3
TRIPPED
4
OFF_2_STA_N
5
OFF_3_STA_N
6
ON_INHIBITED
7
ALARM
8
AT_SETPOINT
9
REMOTE
10
ABOVE_LIMIT
11
reserved
12
reserved
13
reserved
14
reserved
15
reserved
Table 3.7/4:
Main Status Word

DI Status Word (8.05)

Digital input status word of DCS 600 MultiDrive
Bit
Name
0
DI 1
1
DI 2
2
DI 3
3
DI 4
4
DI 5
5
DI 6
6
DI 7
7
DI 8
8
DI 9
9
DI 10
10
DI 11
11
DI 12
12
DI 13
13
DI 14
14
DI 15
15
IOE1
configurable: The DI can be selected for several converter functions; inversion function is available; in addition, it may be used for
application running.
available for programmable Drive: The DI is not selectable for converter functions, but is available for application programming.
Table 3.7/6:
DI Status Word
II F 3-12
Function
ready to close the contactor
ready to generate torque
torque control operating
(running)
indication of fault in DC
Device
1: No OFF2 active
1: No OFF3 active
Switch on inhibited
indication of alarm in DC
Device
Setpoint/act.value monitoring
in the tolerance
1:Remote control / 0:Local
control
speed treshold value (50.10)
reached
(reserved)
(reserved)
(reserved)
(reserved)
(reserved)
Function
configurable
configurable
configurable
configurable
configurable
configurable
configurable
configurable
programmable Drive, if SDCS-IOE-1 is present
programmable Drive, if SDCS-IOE-1 is present
programmable Drive, if SDCS-IOE-1 is present
programmable Drive, if SDCS-IOE-1 is present
programmable Drive, if SDCS-IOE-1 is present
programmable Drive, if SDCS-IOE-1 is present
programmable Drive, if SDCS-IOE-1 is present
1: SDCS-IOE-1 is connected to SDCS-CON-1

Auxiliary Status Word (8.02)

ABB Drive Profile Control Word
Bit
Name
0
LOGG_DATA_READY
1
OUT_OF_WINDOW
EMERG_STOP_CO-
2
AST
3
reserved
4
ON_DISABLED
5
SYNC_RDY
6
FEX1_ACK
7
FEX2_ACK
8
reserved
9
LIMITING
10
TORQ_CONTROL
11
ZERO_SPEED
12
EMF-SPEED
13
FAULT_OR_ALARM
14
DRIVE_DIR_ASW
15
AUTO_RECLOSING
Table 3.7/5:
Auxiliary Status Word
Function
(reserved)
External interlocking
OFF1_N (Digital input
selected by 15.14)
prevents the run
Position counter
synchronous ready status
FEX 1 acknowledge
FEX 2 acknowledge
(reserved)
see signals 8.03, 8.04
Drive is torque controlled
Motor speed actual is zero
EMF speed feedback
selected
Fault or alarm of drive
Negative drive direction
active
auto reclosing logic
activated