Mechanical Disassembly

Mechanical disassembly
1 Projection lens removal
1 Press and hold the lens release button and turn the projection lens anti-clockwise
and then pull out the projection lens.
* See item "Lens Mounting and Removing" for further information.
Projection lens
Lens release button
2 Cabinet top removal
1 Open 2 screw covers-A and remove 2 screws-B (M4x8).
2 Loosen 1 screw-C and turn the lamp cover.
3 Remove 6 screws-D (M4x8) and remove the cabinet top.
d
d
d
d
Lamp cover
c
d
d
a
Screw cover
B
Screw cover
B
Cabinet top
a
Screw cover
-22-