Eiki EIP-HDT30 Service Manual page 128

Chassis no. ke2-hdt3000
Hide thumbs Also See for EIP-HDT30:
Table of Contents

Advertisement

Troubleshooting
Power (DC)
POWER(DC)
S6V
1
2
Power-On
PFC_ON
H
ST_SW
L
DC_ON
H
9
PFC_ON
-6V
7
16V
5
K66B
PFC_ON
DC_ON
IC2601
FA7729
CONTROL
MAIN
SS3.3V
Check that the power control signal
(DC_ON) is correct.
Power-On: H, Standby: L
Stand-by
Q2600
H
L
L
Q2602
Q2603
Q2604
Q2605
IC2604
IC2600
Q2617
FAN5
CTL
Q2609
FAN1
CTL
Q2610
FAN2
CTL
Q2611
FAN
FAN3
CTL
Q2612
FAN4
CTL
Q2613
FAN_SW_1
FAN_SW_2
17
18
15
16
19
17
18
15
16
19
PFC_ON
PFC12V
Q2614
Q2615
FAN5_ERR
FAN1_ERR
FAN2_ERR
FAN3_ERR
FAN4_ERR
K66L
11
10
5
4
3
2
13
14
6
7
8
9
6
6
11
10
5
4
3
2
13
14
6
7
8
9
K8B
PFC
If the Fan error occurs,
the error detection signal
(FAN_ERR) becomes Low.
-128-
MAIN
23
23
Q2601
6V_SW
24
24
SS6V
1
1
2
2
S6V1
11
11
12
12
S6V2
15
15
16
16
S6VPW
37
37
38
38
S6VKS
45
45
46
46
33
33
S6VNIOS
34
34
5
5
S-5V
6
6
27
27
12V
|
|
30
30
19
19
S9.6V
20
20
41
41
S6VFPGA
42
42
49
49
15V_LENS
50
50
K66A
K8A
K66E
FN908
DMD
COOLING
K66D
FN905
CW
COOLING
K66F
FN906
LAMP
COOLING
K66M
FN904
LAMP
COOLING
K66G
FN907
BALLAST
COOLING
K66T
FN909
OPTICAL
COOLING
K66H
FN903
POWER
COOLING
K66J
FN901
EXHAUST
K66K
FN902
EXHAUST
THERMAL
SW
K66P
SW903
THERMAL
K66Q
SW
SW904
LAMP
K66R
COVER SW
SW902
K66N
7
1
2
4
7
1
2
4
K16E
12V

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents