Electrical Adjustment
Grp / No.
Item
22
Measured Blue - Luma
30
Measured Cyan - X
31
Measured Cyan - Y
32
Measured Cyan - Luma
40
Measured Magenta - X
41
Measured Magenta - Y
42
Measured Magenta - Luma
50
Measured Yellow - X
51
Measured Yellow - Y
52
Measured Yellow - Luma
60
Measured Half White - X
61
Measured Half White - Y
62
Measured Half White - Luma
70
Measured Full White - X
71
Measured Full White - Y
72
Measured Full White - Luma
100 Measured Data Update
160
VIDI
0
Brightness (Wheel)-Dynamic
1
Brightness (Wheel)-Not Dynamic Brightness Wheel (Color)
2
Color (Wheel)-Dynamic
3
Color (Wheel)-Not Dynamic
161
Lamp Sync
0
Brightness (Wheel)-x2 Mode
1
Brightness (Wheel)-x3 Mode
2
Color (Wheel)-x2 Mode
3
Color (Wheel)-x3 Mode
200
Option
0
Logo Display Prohibition
1
RS232C Baud rate
4
CABLE SW
5
PW Debug Command Enable
6
Device Refresh Disable
11
HDCP EDID Data Setting
15
Lens Shift Centering Setting *
21
Lamp Warning Time (NORMAL)
22
Lamp Warning Time (ECO)
23
Lamp Warning Time (HIGH)
24
Projector Time REset Times
50
Lamp Replacement Display
51
Filter Warning Display
53
Filter Counter Reset Times
54
Factory Default Executed Times
55
Motor Stop
56
Menu Position (X)
57
Menu Position (Y)
58
Lamp Go Out
59
LENS LOCK Warning Display
62
Color Wheel Warning
65
Peltier PWM Enable
66
Peltier PWM High Term
67
Peltier PWM Low Term
70
ADC Device Select for Analog PC 0 = ISL51002, 1 = PW392 AFE
71
ADC Device Select for Component 0 = ISL51002, 1 = PW392 AFE
72
Component/RGB Auto Switch
80
Destination
100 Disable Auto Picture Control
140 Offset Add Setting Status
141 Offset Add Setting Change
142 Offset Value
143 Offset Add Execute Times
144 Offset Add Cancel Times
201
Option (Signal)
0
FrameLock Option
Function
Execute the update when the value is set to 10.
Brightness Wheel (Brightness)
Brightness Wheel (Brightness)
Brightness Wheel (Color)
0:Menu 1:Forced
0: 19200bps 1: 9600bps
Long Cable 0: Disable 1: Enable
0: Disable (Serial Command Enable)
1: Enable (PW Debug Mode)
0: Enable 1: Disable
0: DVI EDID Data, 1: HDCP EDID Data
Reset Centering position when the value is set to 10.
1:On 0:Off
1:On 0:Off
Read only
Read only
Motor Operation 0: Enable 1: Disable
X Offset
Y Offset
Lamp goes out
0: Enable 1: Disable
0: Enable 1: Disable
Peltier Drive PWM 0: Auto, 1: Manual, 2: Disable
0: Disable 1: Enable
Language Set at Shipping 0:English 1:Japanese
0 : Normal operation 1 : Auto Picture Control Off
0: Not use Offset Add, 1: Use Offset Add (Read only)
Change the Offset Add Setting when the value is set to 10.
Offset Add Value at Shutdwon Temp(Read only)
(Read only)
(Read only)
Frame Lock Setting 1: Normal(PC) 0: OFF
Range
0 - 32767
0 - 1000
0 - 1000
0 - 32767
0 - 1000
0 - 1000
0 - 32767
0 - 1000
0 - 1000
0 - 32767
0 - 1000
0 - 1000
0 - 32767
0 - 1000
0 - 1000
0 - 32767
0 - 10
0 - 10
0 - 10
0 - 10
0 - 10
0 - 65535
0 - 65535
0 - 65535
0 - 65535
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 10
1-16
1-16
1-16
0 - 255
0 - 1
0 - 1
0 - 255
0 - 255
0 - 1
0 - 1024
0 - 1024
0 - 1
0 - 1
0 - 1
0 - 2
0 - 600
0 - 600
0 - 1
0 - 1
0 - 1
0 - 1
0-1
-
0 - 10
-
0 - 255
0 - 255
0 - 1
-50-
Initial
Note
405/184/323/347
0/0/0/0
0/0/0/0
0/0/0/0
0/0/0/0
0/0/0/0
0/0/0/0
0/0/0/0
0/0/0/0
0/0/0/0
310/315/0/0
335/336/0/0
3953/2948/0/0
315/320/307/307
343/350/336/340
11860/7462/10160/11420
-
4
2
5
3
1130
900
429
352
0
0
0
0
0
1
0
4
6
4
0
1
1
0
0
0
0
0
0
0
0
0
600
600
0
0
1
0
Initial: 1 Shipping 0
0
0
0
0
0
1