Temperature Abnormality

temperature monitor operation
The temperature monitor system is provided to prevents
damage of optical components inside a projector from
overheat. Three protection systems are provided. Each
system operation as follows :
the temperature monitor -1:
● to control the air-flow of the cooling fans.
The CPU checks the temperature and atmospheric
pressure inside a projector. It checks a temperature
using temperature sensors IC8821 and IC1381, and it
checks an atmospheric pressure using pressure sen-
sor IC8872. The CPU judges data from sensors and
controls the air flow of the cooling fans so the tem-
perature inside the projector is maintained to normal
temperature.
● to shut down the projector urgently.
The CPU checks temperature of DMD module periph-
ery (IC8821), optical parts periphery (IC1381) and in-
take air (IC8811). If each part temperature reaches
abnormal temperature, the CPU will turn off the pro-
IC8872
PRESS_SENS
PRESS SENSOR
IC1381
IIC
IIC
TEMP. SENSOR
<OPTICAL>
IC301
IC8821
SYSTEM
TEMP. SENSOR
CONTROL
<DMD>
IIC
IC8811
TEMP. SENSOR
<ROOM>
IC4401
FPGA
BALLAST_AC2
BALLAST_AC1
SS3.3V
PFC_ON
AC
F901
SW901
FUSE
MAINS
SWITCH
NOTE : SENSORS OPERATION
■ The sensor's operation is as follows:
IC8872 : Pressure sensor for FAN control
IC1381 : Inside air temperature monitor (Optical)
IC8821 : Inside air temperature monitor (DMD)
IC8811 : Inside air temperature monitor (Room)
TH901 : Peltier device temperature monitor
Temperature sensors location can be seen on
"protections"( page-7).
TH901
P.FAIL
IC5201
FPGA
FAN_SW1
IC7801
DAC
FAN_SW2
Power-on: H
IC1801
Stand-by: L
I/O
DC_ON
EXPANDER
K6A
NOISE
FILTER
POWER(AC)
The temperature
switch is operated?
If the temperature
around FET reaches
105 degrees, a PFC cir-
cuit will be shut down.
jector, and will blink WARNING TEMP. indicator at
intervals of 0.5 seconds. Cooling fans operate until
temperature returns to normal. Indicator will stop blink
when the projector turns on after the temperature re-
turns to normal.
the temperature monitor -2 :
● temperature check of lamps :
Temperature switches (SW903, SW904) are placed
near the lamps. Temperature switches will operate,
if temperature reaches 80ºC. When temperature
switches become open, they cut off PFC12V line, the
power failure "PF_POWER" signal become Low, and
then the CPU will shut down the projector, and the
LAMP indicator is lighting and other indicators are
blinking.
the temperature monitor -3 :
● temperature check of Peltier device :
Peltier device is provided to cool down the DMD mod-
ule. If the temperature of the Peltier device reaches
50ºC, the projector will shut down as the power error.
FAN_ERR
FAN
FAN_DAC
CONTROL
PFC12V
IC2601
Lamp Mode Lamp1 Lamp2 Lamp1/2
PFC_ON1
H
L
FA7729
PFC_ON2
L
H
PFC_ON1
PFC_ON2
PFC_ON: H
POWER(DC)
K16A
K6B
PFC
The temperature switch is
operated?
When the temperature
around a lamp driver bec-
mes abnormally high, the
lamp ballast will be shut
down and a lamp error sig-
nal changes from L to H.
-132-
Check FAN
circuits.
Cooling
Fans
Check the
THERMAL SW
temperature
SW904
switches.
H
H
Opens at 80ªC
THERMAL SW
SW903
LAMP COVER
SW
SW902
X1A
X3A
BALLAST1
K16C
K16B
X1B
X3B
BALLAST2
LED indicators
When the internal temp
error, the WARNING TEMP.
indicator will be blinking.
When the temperature
rises abnormally around
t h e l a m p s 1 o r 2 , t h e
LAMP indicator is lighting
and other indicators are
blinking.
LAMP1