Electrical Adjustment
Grp / No.
Item
254
Fan Control Range Setting
16
Normal Fan Control Min Temp
17
Normal Fan Control Max Temp
18
Normal Fan A Min
19
Normal Fan A Max
20
Normal Fan B/C Min
21
Normal Fan B/C Max
22
Normal Fan D/E Min
23
Normal Fan D/E Max
24
Normal Fan F/G Min
25
Normal FanF/G Max
26
Normal Fan H Min
27
Normal FanH Max
32
Eco1 Fan Control Min Temp
33
Eco1 Fan Control Max Temp
34
Eco1 Fan A Min
35
Eco1 Fan A Max
36
Eco1 Fan B/C Min
37
Eco1 Fan B/C Max
38
Eco1 Fan D/E Min
39
Eco1 Fan D/E Max
40
Eco1 Fan F/G Min
41
Eco1 Fan F/G Max
42
Eco1 Fan H Min
43
Eco1 Fan H Max
48
Eco2 Fan Control Min Temp
49
Eco2 Fan Control Max Temp
50
Eco2 Fan A Min
51
Eco2 Fan A Max
52
Eco2 Fan B/C Min
53
Eco2 Fan B/C Max
54
Eco2 Fan D/E Min
55
Eco2 Fan D/E Max
56
Eco2 Fan F/G Min
57
Eco2 Fan F/G Max
58
Eco2 Fan H Min
59
Eco2 Fan H Max
255
Fan Start/Cooling Setting
0
Fan A Initial Volt
1
Fan B/C Initial Volt
2
Fan D/E Initial Volt
3
FanF/G Initial Volt
4
FanH Initial Volt
8
Cooling Time
10
Temp Error Cooling Time
11
OnStart Cooling Start Threshold
12
After shutdown cooling
256
Fan Lamp Voltage Lower Setting
0
Lamp Voltage
1
Lamp Volt Threshold
2
Fan1 Speed Gain
259
Fan Air Pressure Setting
0
Press Source Range Low
1
Press Source Range High
2
Press Fan Add Range High
3
Press Fan Add Range Low
4
Temp C-A Upward High
5
Temp C-A Upward Low
6
Temp C-A Downward High
7
Temp C-A Downward Low
260
Auto Calibration (Common)
0
Execute Calibration *
1
Loop Count
Function
(Temp/Spinning)
Temp Sensor Control Start/End Temp at Normal
Fan Voltage Set at Normal (Min/Max) (V)
Temp Sensor Control Start/End Temp at Eco1
Fan Voltage Set at Eco1 (Min/Max) (V)
Temp Sensor Control Start/End Temp at Eco2
Fan Voltage Set at Eco2 (Min/Max) (V)
Fan Start Voltage (0.1V)
Cooling Time Setting (x30 sec.) 1: 30 3: 90 15: 450
Cooling Time Setting When the Temp Error occurs (x30 sec.)
1: 30 3: 90 15: 450
Cooling Operation after Shut Down (0: No, 1: Yes)
Current Voltage (V)
Pressure Sensor Control Range Setting (AD)
Pressure Sensor Fan Control Add. Voltage (x0.1)
Fan Voltage Add Upward (Sensor A-D) High
Fan Voltage Add Upward (Sensor A-D) Low
Fan Voltage Add Downward (Sensor A-D) High
Fan Voltage Add Downward (Sensor A-D) Low
Execute Calibration when the Value is changed to 1. (For PC
White 100%)
Max Times of Calibration
Range
L1 L2 L3 L4 L5 L6 L7 L8
20-100
27 27 27 27 27 27 27 27
20-100
37 37 37 37 37 37 37 37
0000-9990
63 63 75 75 75 75 75 63
0000-9990
80 80 80 80 80 80 80 80
0000-9990
50 70 80 80 80 80 80 70
0000-9990
50 70 80 80 80 80 80 70
0000-9990
72 72 72 72 72 72 72 72
0000-9990
138 138 138 138 138 138 138 138
0000-9990
88 88 88 103 103 103 88 88
0000-9990
138 138 138 138 138 138 138 138
0000-9990
75 75 75 75 75 75 75 75
0000-9990
138 138 138 138 138 138 138 138
20-100
27 27 27 27 27 27 27 27
20-100
37 37 37 37 37 37 37 37
0000-9990
50 50 59 59 59 59 59 50
0000-9990
55 55 59 59 59 59 59 55
0000-9990
40 60 70 70 70 70 70 60
0000-9990
40 60 70 70 70 70 70 60
0000-9990
58 58 58 58 58 58 58 58
0000-9990
125 125 125 125 125 125 125 125
0000-9990
78 78 78 78 78 78 78 78
0000-9990
125 125 125 125 125 125 125 125
0000-9990
65 65 65 65 65 65 65 65
0000-9990
120 120 120 120 120 120 120 120
20-100
27 27 27 27 27 27 27 27
20-100
37 37 37 37 37 37 37 37
0000-9990
50 50 59 59 59 59 59 50
0000-9990
55 55 59 59 59 59 59 55
0000-9990
40 60 70 70 70 70 70 60
0000-9990
40 60 70 70 70 70 70 60
0000-9990
70 70 70 70 70 70 70 70
0000-9990
130 130 130 130 130 130 130 130
0000-9990
85 85 85 85 85 85 85 85
0000-9990
130 130 130 130 130 130 130 130
0000-9990
75 75 75 75 75 75 75 75
0000-9990
130 130 130 130 130 130 130 130
0-255
0-255
0-255
0-255
0-255
1-15
1-15
0-100
0-1
0 - 255
30 - 90
0 - 1500
0-1024
0-1024
0 - 2000
0 - 2000
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 1
1 - 30
-55-
Initial
Note
70
70
70
70
70
3
3
50
1
-
30
0
645
325
0
65
25
23
22
21
0
8