Angular Velocity Sensor Output Check And Steadyshot; Check (Ccd-Trv338/Trv438E); Ccd Defect Check - Sony CCD-TRV138 Manual

Adjustments
Hide thumbs Also See for CCD-TRV138:
Table of Contents

Advertisement

12. Angular Velocity Sensor Output Check and
Steadyshot Check (CCD-TRV338/TRV438E)
RadarW
RadarW
RadarW
RadarW
RadarW
Check the angular velocity sensor output.
Precautions on the parts replacement
There are two types of repair parts.
Type A
Type B
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Precautions on angular velocity sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Mode
Subject
Measurement Point
Measuring Instrument
Specified value
Note 1: Check that the data of page: 0, address: 10 is "00".
Note 2: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Switch setting:
1) ZOOM ..................................................................... TELE end
2) STEADYSHOT (Menu setting) ........................................ ON
Checking method:
Order Page Address Data
PITCH sensor output check (SE752 of SI-039 board)
1
0
2
1
YAW sensor output check (SE751 of SI-039 board)
3
0
4
1
5
0
Steadyshot operation check
6
CCD-TRV138/TRV238E/TRV338/TRV438E
ENC03JA
ENC03JB
CAMERA
Not required
Displayed data of page: 1 (Note 2)
Adjusting remote commander
PITCH data: 2680 to 5080
YAW data: 2680 to 5080
Displayed data
Procedure
03
11
With the set in still state,
check that the displayed data
(Note 2) satisfies the PITCH
data specified value.
03
12
With the set in still state,
check that the displayed data
(Note 2) satisfies the YAW
data specified value.
03
00
Shake the set vertically and
horizontally to check that the
steadyshot function operates
normally.

13. CCD Defect Check

Mode
Subject
Measurement Point
Measuring Instrument
Note: Check that the data of page: 0, address: 10 is "00".
Checking method:
Order Page Address Data
1
6
01
2
6
1F
3
6
40
4
5
6
40
6
Processing after completing adjustment:
Order Page Address Data
1
6
01
2
6
40
3
6
1F
6-21
RadarW
RadarW
RadarW
CAMERA
Not required
Check on the monitor TV
Procedure
05
Press PAUSE button.
CC
03
Check on the monitor screen
that no defect is found.
04
Check on the monitor screen
that no defect is found.
Procedure
00
Press PAUSE button.
00
00