General rules

Inspections
The machine must be inspected according to the "Guidelines for Liquid Spray
Devices" at least once every 12 months by a qualified person, to ensure that
continued safe operation is guarateed.
The results of the inspection are to be recorded in writing.
This may be done in any form.
Accident prevention
The machine is designed for accidents to be impossible if used correctly.
The operator is to be notified of the risk of injury from hot machine parts and the
high pressure water jet. The "Guidelines for Liquid Spray Devices" must be
complied with.
Check the oil level at the oil dip stick prior to each use.
(Ensure horizontal position!)
Oil change:
The oil in your high pressure pump should be changed after approx. 40 hours of
operation, or if it takes on a grey or whitish colour. (Formation of condensate)
The oil must be collected in a container and disposed of in accordance with local
rules or legislation.
New oil: 1,0 l - Motor oil: W10-60 SAE Semi-synthetic oil
Ord.-Nr.: 40.059 1
Guarantee
The guarantee period is 12 months according to VDMA.
The guarantee is void if changes are made to the safety devices or if the machine
is used at excess temperatures or speeds. The guarantee is also void if the
machine is used with a voltage below the required rating, with less than the
required amount of water, with dirty water and external damage to the pressure
gauge, nozzle, high pressure hose and spray device.
This guarantee is not applicable for spare parts.