Troubleshooting
Setting Up and Accessing
Problem
Cannot connect to the
GbE2 Interconnect Switch
console interface remotely
using SSH.
Cannot connect to the
GbE2 Interconnect Switch
remotely using the Web
interface.
Cannot connect to the
GbE2 Interconnect Switch
SNMP interface.
J-4
HP CONFIDENTIAL Codename: Strawberry Part Number: 331399-001 Last Saved On: 7/17/03 2:35 PM
continued
Possible Cause
The GbE2 Interconnect Switch IP
address may not be configured or
correct.
The setting allowing access to the
GbE2 Interconnect Switch using
the SSH interface is disabled.
The management network
address/mask (if used) does not
contain the IP address of your
management station.
The GbE2 Interconnect Switch IP
address may not be configured or
correct.
Access to the GbE2 Interconnect
Switch using the Web interface is
disabled.
The Proxy server settings are
configured on your Internet browser
and your proxy server does not
know the GbE2 Interconnect Switch
IP address.
The management network
address/mask (if used) does not
contain the IP address of your
management station.
The GbE2 Interconnect Switch IP
address may not be configured or
correct.
The management network
address/mask (if used) does not
contain the IP address of your
management station.
Possible Solution
From the serial console interface, make
sure that the GbE2 Interconnect Switch IP
address is configured and valid on your
network.
Use the correct IP address to establish
the SSH connection with the GbE2
Interconnect Switch.
From the serial console interface, make sure
that the SSH interface is enabled and all its
settings are configured correctly.
From the serial console interface, make sure
that the Management Network Address/Mask
contains the IP address of your management
station.
From the serial console interface, make
sure that the GbE2 Interconnect Switch IP
address is configured and valid on your
network.
Use the correct IP address to establish
the Web connection with the GbE2
Interconnect Switch.
From the serial console interface, make sure
that the Web interface is enabled.
Disable the manual proxy settings on your
Web browser and let it automatically find Web
servers using the IP address.
From the serial console interface, make sure
that the Management Network Address/Mask
contains the IP address of your management
station.
From the serial console interface, make
sure that the GbE2 Interconnect Switch IP
address is configured and valid on your
network.
Use the correct IP address to establish
the SNMP connection with the GbE2
Interconnect Switch.
From the serial console interface, make sure
that the Management Network Address/Mask
contains the IP address of your management
station.
HP ProLiant BL p-Class GbE2 Interconnect Switch User Guide