Quick Guide
1
1
Normal overload 150% for 1 minute
Adjustable frequency drive
Typical Shaft Output [kW]
Typical Shaft Output [HP]
IP 20
Output current
Max. input current
Table 1.16 Line Power Supply 3x380–480 V AC
1.
At rated load conditions.
1-18
®
VLT
Continuous (3x380–440 V) [A]
Intermittent (3x380–440 V) [A]
Continuous (3x440–480 V) [A]
Intermittent (3x440–480 V) [A]
Max. cable size:
2
(line power, motor) [mm
/AWG]
Continuous (3x380–440 V) [A]
Intermittent (3x380–440 V) [A]
Continuous (3x440–480 V) [A]
Intermittent (3x440–480 V) [A]
Max. electrical fuses [A]
Environment
Estimated power loss hp [W], Best case/
Typical
1)
Weight enclosure IP20 (lb [kg])
Efficiency [%], Best case/
Typical
1)
MG02B722 - VLT
Micro Drive Quick Guide
P5K5
P7K5
5.5
7.5
7.5
10
Frame
Frame
M3
M3
12.0
15.5
18.0
23.5
11.0
14.0
16.5
21.3
4/10
19.2
24.8
27.4
36.3
16.6
21.4
23.6
30.1
0.176
0.235
[131.0]/
[175.0]/
0.224
0.292
[166.8]
[217.5]
6.6 [3.0]
6.6 [3.0]
98.0/
98.0/
97.5
97.5
®
is a registered Danfoss trademark
P11K
P15K
P18K
11
15
18.5
15
20
25
Frame
Frame
Frame
M4
M4
M5
23.0
31.0
37.0
34.5
46.5
55.5
21.0
27.0
34.0
31.5
40.5
51.0
16/6
33.0
42.0
34.7
47.5
60.0
49.0
29.0
36.0
31.5
41.0
52.0
44.0
See 1.3.4 Fuses
0.389
0.519
0.530
[290.0]/
[387.0]/
[395.0]/
0.459
0.609
0.574
[342.0]
[454.0]
[428.0]
97.8/
97.7/
98.1/
97.4
97.4
98.0
P22K
22
30
Frame
M5
43.0
64.5
40.0
60.0
41.2
57.6
37.5
53.0
0.626
[467.0]/
0.697
[520.0]
98.1/
97.9
Need help?