5 - 1 5 0
The IP Fragmented Packets alarm alerts the switch personnel of a
potential security problem. The Threshold Alarm Level view (RC/V
8.29) is used to enable or disable the alarm.

This procedure is executed to enable the IP Fragmented Packets

Alarm. By default the alarm is disabled.

Refer to 235-118-258, Recent Change Reference for information on
the RC/V system.
Disabling the alarm could cause a security problem to go unnoticed
by the switch personnel.
Required Tools
Supplemental Trunk Line Workstation (STLWS) or Recent
Change and Verify (RC/V) terminal
Access to RC/V Menu Interface
Required Material
®
The 5ESS
release or later with the SIP for Packet Trunking - NAR feature
software.
Required Information
None.
Required Conditions
None.
............................................................................................................................................................
Select and prepare terminal for RC/V activities.
1
Reference:
"Select and Prepare Terminal" (5-11)
............................................................................................................................................................
Type and enter the RC/V form number.
2
8.29
Lucent Technologies
switch must be running a 5E16.2 FR3 software
Provisioning
235-200-118
Issue 3.02B, March 2007