Danfoss MCO 305 Operating Instructions Manual page 30

Programmable motion controller
Hide thumbs Also See for MCO 305:
Table of Contents

Advertisement

Troubleshooting
Error no.
LCP display
195
Too many testindices
196
Code too old
198
Limit sw. violation
199
Internal MCO fault
Error 102
Too many CAN objects have been used and there are no more CAN objects available. The optional error information (see
Error History) is used as follows:
CN_TIMEOUT
NO_HARDWARE
NO_MEMORY
NO_CANMEMORY
NO_MOBJ
CN_CANERROR
CN_MOBJ_DIRERR
NO_USER
SDO_ABORT
SDO_ID_NOT_IN_USE
SDO_SEG_ARRAY_TOO_SMALL
SDO_SEG_TOGGLE_ERROR
SDO_SEG_TOO_MUCH_DATA
SDO_SEG_NOT_ENOUGH_DATA
SDO_SEG_ARRAY_WRITE_ERROR
GUARD_ERROR_NOT_OPERATIONAL
GUARD_ERROR_TOGGLE
GUARD_ERROR_MODULE_NOT_RESPONSE
GUARD_ERROR_NO_MODULE
Error 103
Illegal axis number
An attempt has been made to find an axis which does not
exist in the controller.
Check to see if the program axis command has an invalid
number or a general axis command (...X(*)).
Error 105
Error not reset
An attempt has been made to execute a motion
command, although an actual error message has not been
cleared.
Error 106
Home not done
Failed to move to HOME position. According to the axis
33-00 Force HOME, a forced move to the machine zero-
point is demanded, before other motion commands can be
executed. This move to the machine zero-point has not
been executed.
Error 107
Home velocity zero
An attempt was made to execute the HOME command but
the motor is set to 0 in 33-03 Velocity of Home Motion.
MCO 305 Operating Instructions
Error text
Too many test indices in data logging command.
Code is too old for the current firmware.
rong direction after limit switch tripped and error reset.
Internal MCO fault
-2
// timeout of CAN commands when sending or reading telegrams
-6
// no CAN hardware present
-7
// no more entries available (mailboxes or lists)
-10
// no more mailboxes available for define command
-11
// the demanded mailbox is not available
-12
// a CAN bus error is detected (low level bus error)
-13
// direction of mailbox is wrong (try to read a write box or vice versa)
-33
// return value for sdo state (SDOSTATE).
-50
// has to be higher than the CN_ error messages
-33
// return value for sdo state (SDOSTATE )
-51
-52
-53
-54
-55
®
MG.33.K3.02 - VLT
is a registered Danfoss trademark
-101
-102
-103
-104
Error 108
Position error
HOME was executed with HOME_VEL set to zero.
The distance between the set and the real position was
greater than the Maximum Tolerated Position Error defined
in 32-67 Max. Tolerated Position Error.
Causes:
-
Mechanically blocked or overloaded frequency
converter,
-
32-67 Max. Tolerated Position Error too small,
-
commanded speed greater than VLT
AutomationDrive 4-13 Motor Speed High Limit
[RPM] and 3-03 Maximum Reference,
-
commanded acceleration too great,
-
32-60 Proportional factor too small, or
-
VLT AutomationDrive not enabled.
7
7