Station Status And Translation Audits And Updates Test (#36) - Avaya G700 Maintenance Manual

Gateway/ server or an
Hide thumbs Also See for G700:
Table of Contents

Advertisement

6 Avaya MultiVantage Software-Controlled Maintenance:
Table 48. TEST #35 Battery Feed Test Continued
Error
Test
Code
Result
2000
ABORT
2100
ABORT
FAIL
PASS
Station Status and Translation Audits and
Updates Test (#36)
For an analog line port that is administered as an external alarm, this test is limited to updating the
software with the switchhook state.
Table 49. TEST #36 Station Status and Translation Audits and Updates
Error
Code
1004
1006
2000
104
Description/Recommendation
Response to the test request was not received within the allowable
time period.
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals for a maximum of 5 times.
The port's battery feed chip is unable to supply sufficient power to
sense the external device alarm. This may occur when the test is
performed at the same time that the external device contact closure
occurred.
Enter test external-device-alarm port GGGVSpp to determine if
the port is reporting an EXT-DEV failure before retesting. Wait until
the port has no EXT-DEV failure before retesting.
Retry the command at 1-minute intervals for a maximum of 5 times.
The port's battery feed chip is able to provide power to the external
device alarm to detect contact closure.
Test
Description/Recommendation
Result
ABORT
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals for a maximum of 5 times.
ABORT
The port received an EXT-DEV failure during the test. The test has
been aborted.
Enter test external-device-alarm port GGGVSpp to determine if
the port is reporting an EXT-DEV failure before retesting.
If the port has no EXT-DEV failure, retry the command at 1-minute
intervals for a maximum of 5 times.
ABORT
This port has been busied out by command.
Check Error Log for Error Type 18 (port busied out). If present,
release the port with the release port command and run the test
again.
ABORT
Response to the test request was not received within the allowable
time period.
ALARM-PT (ALARM PORT)
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002