Supplement; Technical Data; Supplement 9.1 Technical Data - Vega VEGABAR 17 Operating Instructions Manual

Process pressure transmitter with metallic measuring cell
Table of Contents

Advertisement

9

Supplement

9.1

Technical data

General data
Parameter, pressure
Measuring principle
Communication interface
Materials and weights
Materials, wetted parts
Ʋ Process fitting
Ʋ Diaphragm
Ʋ Diaphragm with front flush version
Ʋ O-ring seal with front-flush version
Ʋ Flat seal process fitting thread G½
(EN 837)
Materials, non-wetted parts
Ʋ Internal transmission liquid
Ʋ Housing
Ʋ Terminal housing
Ʋ Ground terminal
Ʋ Plug
Ʋ Cable gland
Ʋ Plug seal
Ʋ Connection cable
Available cable length max.
Weight approx.
Ʋ Version with plug connector, cable
outlet
Ʋ Version with terminal housing
Torque max.
Input variable
The availability of the respective measuring range depends on the corresponding process fitting.
The specifications concerning overload capacity are only an overview and refer to the measuring
cell. Limitations due to the material and form of the process fitting are possible. The specifications
on the type label always apply.
Synthetic oil: For measuring ranges up to 16 bar, FDA listed for the food processing industry. For measuring
2)
ranges up to 25 bar not available.
Halocarbon oil: With version oil and greasefree, not with vacuum measuring ranges, not with absolute measur-
3)
ing ranges < 1 bar
.
abs
VEGABAR 17 •
Gauge pressure, absolute pressure, vacuum
Piezoresistive/Thin film DMS
None
316Ti
316Ti
316Ti, Alloy C4
FPM, FKM, NBR
Aramide fibres, bound with NBR
Synthetic oil, Halocarbon oil
316Ti
316Ti
316Ti
PA
PA, 316Ti
Silicone
PUR
40 m
0.2 kg (0.441 lbs)
0.35 kg (0.772 lbs)
50 Nm (36.88 lbft)
9 Supplement
2)3)
23