HIOS HM-10 Operation Manual page 8

The torque value checking meters for automatic controlled system
Table of Contents

Advertisement

9. Turn the screwdriver for measurement.
When the clutch is disconnected, the spring is compressed.
The measurement is displayed in the window and saved.
This is the output torque of the screwdriver.
10. Let Fidaptor recover from contraction to return to the constant height.
*Use the handy screwdriver to loosen the threaded shaft.
(Note) Always let the spring recover the constant height by loosening.
11. Cancel the value in the window by pushing the Reset button.
POWER
O N
OFF
RESET
RESET button for cancelling the value
12. Repeat the steps 10 to 12 to determine average output torque.
Furthermore, if you want to set any torque, adjust the screwdriver's nut for torque adjustment and
follow the same procedure.
13. When you finish measurements, always loosen Fidaptor.
At the end of the operation for the day, turn off the power and remove everything from the socket.
(Note) Make sure to loosen the Fidaptor spring at the end of operation and store it.
When the clutch of the screwdriver
is disconnected, the measured
value is displayed in the window
and saved.
◎Important
The target looseness is that "the
spring can be turned with the fingers"
to always have a constant height.
*Note for resetting
(1) Let Fidaptor return to the constant height before
HM
(2) Let the socket section have no load.
(Note) It cannot be reset if there is a load.
N m
lbf in
kgf cm
MODE
PEAK
TRAK
MADE IN JAPAN
- 7 -
21.3
pushing the RESET button for cancelling the value.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hm-100

Table of Contents