Download Print this page
HIOS HIT Series Owner's Manual

HIOS HIT Series Owner's Manual

Impact torque meters

Advertisement

Quick Links

1-35-1 Oshiage, Sumida-ku Tokyo, Japan 131-0045
21A
Impact Torque Meters
HIT-Series
HIT-200
HIT-500
HIT-2000
Owner's Manual
(March 2021)
TEL: 81 (Japan) 3-6661-8821
FAX: 81 (Japan) 3-6661-8828
Operation Manual No.: ET-C002

Advertisement

loading

Summary of Contents for HIOS HIT Series

  • Page 1 Impact Torque Meters HIT-Series HIT-200 HIT-500 HIT-2000 Owner’s Manual (March 2021) 1-35-1 Oshiage, Sumida-ku Tokyo, Japan 131-0045 TEL: 81 (Japan) 3-6661-8821 FAX: 81 (Japan) 3-6661-8828 Operation Manual No.: ET-C002...
  • Page 2 ■ Introduction HIT Digital Torque Meters directly measure torque of impact drivers, pneumatic drivers, clutch-type torque wrenches, etc. Its first peak circuit gives high accuracy of torque of impact drivers. Battery powered and easily brought to the assembly line or work place, you will find it extremely handy to use. It can be connected to a printer for greater usefulness in quality control.
  • Page 3 ■ Parts BUZZ SET PRINTER OUTPUT CONNECTOR ANALOG OUTPUT CONNECTOR CONNECT FOR CHARGER DISPLAY PANEL POWER SWITCH UNIT CONVERTER SWITCH DISPLAY UNIT MODE SWITCH RESET BUTTON DETECTOR CORD (No.: DPC-0506) ZERO ADJUSTING KNOB DETECTOR UNIT RESET BUTTON SOCKET ● Printer output connector The meter performs recording of data, structuring them into statistics, compute processing and also can be connected to personal computers, thus can be developed to high quality information processing system.
  • Page 4: Operation

    ■ Operation First check the battery level! Turn the power switch on. If the charge is inadequate, the message "LOBAT" will be displayed. In that case, recharge the battery for about 3 hours. Never recharge for more than 8 hours. 1.
  • Page 5 5. When using a printer set the mode switch to "Peak." When peak measurement is desired, set the Mode Switch at PEAK. The peak value is held for more than 5 seconds when more than 15 digits signals are inputted. It can be cancelled by pushing the reset button. (There are reset buttons on the display and the detector unit.) 6.
  • Page 6 When using with these products, please refer to the appropriate operation manuals. ■ Inspection and calibration The detecting element of the HIOS Digital Torque Meter has a specially designed structure and maintains its stabilized load accuracy over a long period of time. However at least once a year inspections are required to get the best use from the Meter.
  • Page 7 ■ Outer view of detector unit 4-Ø6.2 HIT-200 4-Ø6.2 HIT-500 12.7 HIT-2000 - 7 -...
  • Page 8 ■ Specifications Model No. HIT-200 HIT-500 HIT-2000 N•m 0.15 - 18.00 1.5 - 50.0 25.0 - 180.0 Peak mode lbf•in 1.5 - 160.0 1.5 - 440 250 - 1600 measuring range kgf•cm 1.5 - 180.0 15 - 500 250 - 1800 Accuracy ±1 % (+ 1 digit) F.
  • Page 9 ■ ANALOG OUTPUT SPECIFICATIONS Load Impedance > 1 kΩ 1 digit ≅ 1 mV ■ OUTPUT SPECIFICATIONS Connector pin location MITSUTOYO MQ65-5P DATA: data output in the format shown CK: clock REQ: request for data output : Open drain -0.3 - +7V (400 µA max.) Pull up to V (1.55V) Data output format...
  • Page 10 ■ The following table is for CHINA RoHS2 If you are asked by China Customs, please show this table to them. 有害物质名称及含量标识格式 产品中有害物质的名称及含量 部件名称 有害物質 铅(pb) 汞 (Hg) 镉 (Cd) 六价铬 多溴联苯 多溴二苯醚 (CR(VI)) (PBB) (PBDE) 充电池 ○ ○ ○ ○...