HIOS Digital Torque Meters
HDP-50
HDP-5
(
)
HDP-100
Option
Operation manual
(May 2017)
17A
Operation manual No. ET−C007
Utilizing 100% post-consumer
recycled paper pulp

Advertisement

Table of Contents
loading

Summary of Contents for HIOS HDP-50

  • Page 1 HIOS Digital Torque Meters HDP-50 HDP-5 HDP-100 Option Operation manual (May 2017) Operation manual No. ET−C007 Utilizing 100% post-consumer recycled paper pulp...
  • Page 2: Table Of Contents

    Easy to use, accurate and low in cost, HIOS digital torque meters are used by manufacturers of electronic goods, cameras, watches and other kinds of precision instruments, as well as by makers of automobiles and aircraft.
  • Page 3: Safety Precautions

    • When using the support arm that comes with Places subject to vibration, dust or hot air. • Model HDP-50, be sure to attach it securely to Outdoors, or places where electrical discharges • prevent it from coming loose under high torque may occur.
  • Page 4: Hios Digital Torque Meter Controls And

    ■ HIOS Digital Torque Meter controls ■ Items included with torque meter Market Sensor Support Model Areas Unit Cord Exclusive Battery Charger 1 pc. (See p4) HIOS shank ∅4 +Bit #0 × 40 mm 220 Volt Adaptor Plug HDP-5 #1 × 40 mm China #2 ×...
  • Page 5: Functions

    Please push the power switch and detach it immediately until a buzzersounds. Statistical Process Control (SPC) uses statistical techniques to monitor variations in manufacturing processes for use in quality control. Support arm (comes with Model HDP-50/HDP-100) Use the support arm when measured torque is too high for the operator to control Support arm without assistance.
  • Page 6: Operating Procedure

    5. Set 【 MODE 】 switch to "PEAK" or "F.PEAK." • In peak mode the peak torque value reached dur- ing measurement is displayed. Thus, the display does not change. Model HDP-50 measures up to 10 N m of torque, which corresponds to a dis- •...
  • Page 7: Explanations Of Functions

    ■ Explanations of functions ting has been changed. The torque setting can be changed as desired. The warning tone signals that DIP switch the set torque value has been measured. Always turn off the power before Example (torque set at 100) changing DIP switch settings.
  • Page 8: Memory

    Memory Fig. 1 Recording readout Objective Example of memory readout Memory mode on (LED on) Measurement data can be stored in the memory for Ready for management of everyday operations. measurement Sensor unit bit exerts torque on screw. Storing and reading out measurement data Setting screw torque When the memory function is on, pressing this 1.
  • Page 9: Average Torque Measurement

    Makes possible measurement of the minimum, ■ Battery charger average and maximum values among sets of mea- To charge batteries for the HIOS torque meter use surements, each set consisting of up to ten measure- only the battery charger provided with the meter.
  • Page 10: Types Of Data Output

    HIOS torque meters employ a unique sensor mech- rect operation. anism that maintains accuracy for long periods. We recommend that the torque meter be sent in to HIOS ■ Customer service Corporation for inspection at least once a year. (Note that a fee is charged for this service.)
  • Page 11: Troubleshooting

    ■ Troubleshooting Before you conclude the torque meter is broken, go through the following troubleshooting guide. If, by fol- lowing the instructions, you are unable to resolve the difficulty, please contact HIOS Corporation or your HIOS dealer. Problem Causes Resolving the problem •...
  • Page 12: External Features Diagram

    M_CR Unit: mm • Both Model HP-100 and HP-10 have the same dimensions. Note that specifications or the external appearance of HIOS torque meters are subject to change without no- tice. ■ Analog and data output specifications A display of 500 means approximately 0.5 volt.
  • Page 13: China Rohs2 Table

    ■ China RoHS2 Table If you are asked by China Customs, please show this table to them. In addition, the China RoHS marks also is required at the product and product box. At the product, you can find it at the bottom and it is marked on the product box. If you cannot find the mark, please ask your distributor.
  • Page 16 1-16-5 Akiyama, Matsudo City, Chiba Pref., Japan TEL: 81 (Japan) 47-392-2001 FAX: 81 (Japan) 47-392-7773...

This manual is also suitable for:

Hdp-5Hdp-100