■ Specifications

Model
Peak measuring range
Accuracy
Battery pack
Charging time
Weight (kg)
Continuous operating time on a full charge
Battery life
Detector cord
Exclusive battery charger
● Never apply the load more than the maximum allowable load.
● We cannot guarantee the life of the battery in the specification table because it varies depending
on the usage pattern.
● Instruments for use in foreign countries are also available (input: AC120V, 220-240V).
N ・ m
0.015-1.000
lbf ・ in
0.15 - 9.00
N ・ cm
1.5-100.0
Display unit
Detector
1.7m (6P cord), P/N: DPC-0506
Input: AC100V, 120V, 220-240V
HM-10
HM-100
0.15-10.00
1.5 - 90.0
15-1000
Within ±0.5% (F.S.)
6V NiMH
8 hours or less
1.0kg
0.35kg
30 hours
300 cycles of charging
Output: DC7.2V 120mA
(P/N: TCH-100N)
- 14 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hm-100